Ground Return Current Behaviour in High Voltage Alternating Current Insulated Cables
Open Access
- 3 December 2014
- Vol. 7 (12) , 8116-8131
Abstract
The knowledge of ground return current in fault occurrence plays a key role in the dimensioning of the earthing grid of substations and of cable sealing end compounds, in the computation of rise of earth potential at substation sites and in electromagnetic interference (EMI) on neighbouring parallel metallic conductors (pipes, handrails, etc.). Moreover, the ground return current evaluation is also important in steady-state regime since this stray current can be responsible for EMI and also for alternating current (AC) corrosion. In fault situations and under some assumptions, the ground return current value at a substation site can be computed by means of k-factors. The paper shows that these simplified and approximated approaches have a lot of limitations and only multiconductor analysis can show the ground return current behaviour along the cable (not only the two end values) both in steady-state regime and in short circuit occurrence (e.g., phase-to-ground and phase-to-phase-to-ground). Multiconductor cell analysis (MCA) considers the cable system in its real asymmetry without simplified and approximated hypotheses. The sensitivity of ground return current on circuit parameters (cross-bonding box resistances, substation earthing resistances, soil resistivity) is presented in the paper.Keywords
This publication has 15 references indexed in Scilit:
- Multiconductor cell analysis of skin effect in Milliken type cablesElectric Power Systems Research, 2012
- Harmonic behaviour of HVDC cablesElectric Power Systems Research, 2012
- Determination of Steady-State and Faulty Regimes of Overhead Lines by Means of Multiconductor Cell Analysis (MCA)Energies, 2012
- Multiconductor analysis of underground power transmission systems: EHV AC cablesElectric Power Systems Research, 2009
- Distribution Line Carrier: Analysis Procedure and Applications to DGIEEE Transactions on Power Delivery, 2006
- High-Capability Applications of Long Gas-Insulated Lines in StructuresIEEE Transactions on Power Delivery, 2006
- Ground fault current distribution in stations supplied by a line composed of a cable and an overhead sectionEuropean Transactions on Electrical Power, 2006
- Determination of the reduction factor for feeding cable lines consisting of three single-core cablesIEEE Transactions on Power Delivery, 2003
- Efficient reduction of fault current through the grounding grid of substation supplied by cable lineIEEE Transactions on Power Delivery, 2000
- Practical method for evaluating ground fault current distribution in station, towers and ground wireIEEE Transactions on Power Delivery, 1998