Application of Prandtl’s Theory in the Design of an Experimental Chamber for Static Pressure Measurements
Open Access
Abstract
Pumping in vacuum chambers is part of the field of environmental electron microscopy. These chambers are separated from each other by a small-diameter aperture that creates a critical flow in the supersonic flow regime. The distribution of pressure and shock waves in the path of the primary electron beam passing through the differentially pumped chamber has a large influence on the quality of the resulting microscope image. As part of this research, an experimental chamber was constructed to map supersonic flow at low pressures. The shape of this chamber was designed using mathematical–physical analyses, which served not only as a basis for the design of its geometry, but especially for the correct choice of absolute and differential pressure sensors with respect to the cryogenic temperature generated in the supersonic flow. The mathematical and physical analyses presented here map the nature of the supersonic flow with large gradients of state variables at low pressures at the continuum mechanics boundary near the region of free molecule motion in which the Environmental Electron Microscope and its differentially pumped chamber operate, which has a significant impact on the resulting sharpness of the final image obtained by the microscope. The results of this work map the flow in and behind the Laval nozzle in the experimental chamber and are the initial basis that enabled the optimization of the design of the chamber based on Prandtl’s theory for the possibility of fitting it with pressure probes in such a way that they can map the flow in and behind the Laval nozzle.Keywords
This publication has 26 references indexed in Scilit:
- The low‐temperature method for study of coniferous tissues in the environmental scanning electron microscopeMicroscopy Research and Technique, 2014
- Physical and Bioengineering Properties of Polyvinyl Alcohol Lens-Shaped Particles Versus Spherical Polyelectrolyte Complex Microcapsules as Immobilisation Matrices for a Whole-Cell Baeyer–Villiger MonooxygenaseApplied Biochemistry and Biotechnology, 2014
- Imaging of early conifer embryogenic tissues with the environmental scanning electron microscopeBiologia plantarum, 2012
- Velocity and ejector-jet assisted differential pumping: Novel design stages for environmental SEMMicron, 2012
- Figure of merit for environmental SEM and its implicationsJournal of Microscopy, 2011
- Beam transfer characteristics of a commercial environmental SEM and a low vacuum SEMJournal of Microscopy, 2010
- Scintillation SE detector for variable pressure scanning electron microscopesJournal of Microscopy, 2010
- Optimum beam transfer in the environmental scanning electron microscopeJournal of Microscopy, 2009
- Modeling and experiments on differential pumping in linear plasma generators operating at high gas flowsJournal of Applied Physics, 2009
- Environmental scanning electron microscopy and microanalysisMicrochimica Acta, 1994