Experimental validation of uterine artery volume blood flow measurement by Doppler ultrasonography in pregnant sheep
- 27 March 2007
- journal article
- research article
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 29 (4) , 401-406
Abstract
Objective: To test the hypothesis that Doppler‐derived (calculated) uterine artery volume blood flow (cQUtA) reflects accurately volume blood flow measured directly (mQUtA) in an experimental setting.Methods: Five pregnant sheep were instrumented at 122–130 days of gestation under general anesthesia. After a 4‐day recovery period, maternal hemodynamics were varied by administering to the sheep under general anesthesia noradrenaline, beta‐blocker, low oxygen gas mixture, epidural bupivacaine and ephedrine, consecutively. The central venous pressure was obtained with the help of a thermodilution catheter. The mean arterial pressure and acid–base status were monitored using a 16‐gauge polyurethane catheter inserted into the descending aorta via a femoral artery. A 6‐mm transit‐time ultrasonic perivascular flow probe was used to measure the mQUtA. Doppler ultrasonography of the uterine artery was performed and volume blood flow was obtained simultaneously by the transit‐time ultrasonic perivascular flow probe during each phase of the experiment.Results: A total of 31 observations were made. The mQUtA varied between 90 and 800 (mean ± SD, 419 ± 206) mL/min during the experiments. The corresponding values for the cQUtA were 110 and 900 (mean ± SD, 459 ± 211) mL/min. There was a significant correlation (R = 0.76; P < 0.0001) between mQUtA and cQUtA. The mQUtA correlated positively with Doppler‐derived uterine artery absolute velocities, i.e. peak systolic (R = 0.50; P = 0.004), end‐diastolic (R = 0.53; P = 0.002) and time‐averaged maximum (R = 0.69; P < 0.0001) and time‐averaged intensity weighted mean (R = 0.75; P < 0.0001) velocities.Conclusion: cQUtA correlates well with volume blood flow measured directly. Doppler‐derived uterine artery absolute blood flow velocities reflect uteroplacental volume blood flow in pregnant sheep. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Doppler‐derived umbilical artery absolute velocities and their relationship to fetoplacental volume blood flow: a longitudinal studyUltrasound in Obstetrics & Gynecology, 2005
- Reference ranges for umbilical vein blood flow in the second half of pregnancy based on longitudinal dataPrenatal Diagnosis, 2005
- Applying the right statistics: analyses of measurement studiesUltrasound in Obstetrics & Gynecology, 2003
- Longitudinal quantification of uterine artery blood volume flow changes during gestation in pregnancies complicated by intrauterine growth restrictionBJOG: An International Journal of Obstetrics & Gynaecology, 2003
- Comparison of steady-state diffusion and transit time ultrasonic measurements of umbilical blood flow in the chronic fetal sheep preparationAmerican Journal of Obstetrics and Gynecology, 1996
- Volume blood flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation studyClinical Physiology and Functional Imaging, 1993
- Color Doppler imaging of the uterine artery in pregnancy: normal ranges of impedance to blood flow, mean velocity and volume of flowUltrasound in Obstetrics & Gynecology, 1992
- Inter- and intra-observer variability of Doppler peak velocity measurements: An in-vitro studyUltrasound in Medicine & Biology, 1990
- Measurement of blood flow by ultrasound: Accuracy and sources of errorUltrasound in Medicine & Biology, 1985
- Methodology and basic problems related to blood flow studies in the human fetusUltrasound in Medicine & Biology, 1984