Long-Term Mechanical Circulatory Support in 198 Patients: Largest Single-Center Experience Worldwide
Authors:
- Thorsten DrewsTDThorsten Drews
- Michael DandelMDMichael Dandel
- Thomas KrabatschTKThomas Krabatsch
- Evgenij PotapovEPEvgenij Potapov
- Alexander StepanenkoASAlexander Stepanenko
- Ewald HennigEHEwald Hennig
- Hans Brendan LehmkuhlHLHans Brendan Lehmkuhl
- Miralem PasicMPMiralem Pasic
- Yuguo WengYWYuguo Weng
- Roland HetzerRHRoland Hetzer
- 1 January 2011
- journal article
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 57 (1) , 9-16
Abstract
During recent years, mechanical circulatory support (MCS) devices have been increasingly used for long-term support. Nevertheless, problems of embolic and bleeding complication, infections, and technical failure still inhibit successful permanent support. We analyzed the courses of 198 patients who were supported for >1 year by 12 different MCS devices. Of the 198 patients, 87 had first-generation MCS devices (pulsatile), 43 second-generation devices (nonpulsatile with standard bearings), and 68 third-generation devices (nonpulsatile with magnetic bearings), implanted between July 1994 and March 2009. The mean time on support of the total group was ∼ 2 years (690 ± 321 [366-1,875] days). Of the first generation, 83 patients (95%) could be discharged; in the second and third group, all patients could be discharged. Rehospitalizations were observed in all patients. Reasons for readmission were coagulation disorders, wound infections, stroke, and technical failure. Seventy-seven patients received heart transplantation, 66 are still receiving support, 53 died, and two patients have been weaned from the device. All types of devices can be used for extended periods of time. Device- and nondevice-related rehospitalizations were observed in all three groups of patients. Close outpatient monitoring and support are crucial to ensure good long-term results.Keywords
This publication has 11 references indexed in Scilit:
- Mechanical Circulatory Support in Patients of Advanced AgeEuropean Journal of Heart Failure, 2010
- Renal Function After Implantation of Continuous Versus Pulsatile Flow Left Ventricular Assist DevicesThe Journal of Heart and Lung Transplantation, 2008
- End-organ Function in Patients on Long-term Circulatory Support With Continuous- or Pulsatile-flow Assist DevicesThe Journal of Heart and Lung Transplantation, 2007
- Third‐generation Blood Pumps With Mechanical Noncontact Magnetic BearingsArtificial Organs, 2006
- Biventricular Assist Device-Induced Right Ventricular Reverse Structural and Functional RemodelingThe Journal of Heart and Lung Transplantation, 2005
- Long-Term Results in Patients With Idiopathic Dilated Cardiomyopathy After Weaning From Left Ventricular Assist DevicesCirculation, 2005
- Permanent mechanical circulatory support in patients of advanced ageEuropean Journal of Cardio-Thoracic Surgery, 2004
- Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device supportThe Annals of Thoracic Surgery, 2004
- Kardiale Assist-Systeme - Gegenwärtiger StandHerz, 2002
- Infection during circulatory support with ventricular assist devicesThe Annals of Thoracic Surgery, 1999