Identification of Terminal Connection and System Function for Sensitive Frequency Response Measurement on Transformers
Authors:
- 31 March 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 23 (2) , 742-750
Abstract
Frequency response measurement on a transformer is a low voltage, off-line exercise. So, it virtually permits determination of any network/system function, by imposing any desired terminal condition for the nontested windings. The terminal conditions employed have significant influence on the achievable fault detection ability, and maximizing this ability should obviously be one of the main aims of frequency response measurements. Simply stated, this requirement translates to the ability to identify/measure as many natural frequencies as possible. However, there is a practical limitation that not all network/system functions can exhibit all natural frequencies. Hence, it is necessary to determine the most appropriate combination of terminal connection and system function for achieving this objective. Considering a two-winding transformer representation, system functions for different terminal conditions were computed. Depending on number of natural frequencies distinguishable in the amplitude frequency response of a system function, each measuring condition was ranked. Thus, it led to identification of the best configuration. Later, these findings were verified on an actual transformer. Performance of best configuration was compared with currently employed low-voltage impulse (LVI) test (used during short-circuit testing of transformers) and sweep frequency response measurement test conditions, and found to be better. In conclusion, it is believed that after adequate field verifications, the identified configuration can be declared as the preferred way of making frequency response measurements on transformers.Keywords
This publication has 10 references indexed in Scilit:
- Improved Detection of Power Transformer Winding Movement by Extending the FRA High Frequency RangeIEEE Transactions on Power Delivery, 2005
- Transformer winding movement monitoring in service - key factors affecting FRA measurementsIEEE Electrical Insulation Magazine, 2004
- Detection of transformer winding deformations based on the transfer function—measurements and simulationsMeasurement Science and Technology, 2003
- Transfer function method to diagnose axial displacement and radial deformation of transformer windingsIEEE Transactions on Power Delivery, 2003
- Detection of shorted turns and winding movements in large power transformers using frequency response analysis2002
- Structure of transfer function of transformers with special reference to interleaved windingsIEEE Transactions on Power Delivery, 2002
- INFLUENCE OF SECONDARY WINDING TERMINAL CONDITIONS ON IMPULSE DISTRIBUTION IN TRANSFORMER WINDINGSElectric Machines & Power Systems, 1993
- Transformer Diagnostic Testing by Frequuency Response AnalysisIEEE Transactions on Power Apparatus and Systems, 1978
- Influence of Phase Connection and Terminal Conditions on Natural Frequencies of Three-Phase Transformer WindingsIEEE Transactions on Power Apparatus and Systems, 1968
- Survey and Classification of Publisled Data on the Surge Performance of Transformers and Rotating MachinesTransactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1958