Density heterogeneities and the influence of multiple Coulomb and nuclear scatterings on the Bragg peak distal edge of proton therapy beams
Authors:
- Gabriel O SawakuchiGSGabriel O Sawakuchi
- Uwe TittUTUwe Titt
- Dragan MirkovicDMDragan Mirkovic
- Radhe MohanRMRadhe Mohan
- 4 August 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (17) , 4605-4619
Abstract
Density heterogeneities in the path of proton beams are known to cause degradation of the Bragg peak and, thus, widening of its distal fall-off. Inadequate accounting for this effect may lead to unwanted dose delivered to normal tissue distal to the target volume. In low-density regions, such as the thorax, this may lead to large volumes of healthy tissue receiving unnecessary dose. Although it is known that multiple Coulomb scattering within the density heterogeneities is the main cause of Bragg peak degradation, no systematic attempt has been made to quantify the contribution of multiple Coulomb scattering and nuclear scattering. Through a systematic study using a 220 MeV proton beam, we show that nuclear scattering contributes to about 5% of the distal fall-off width and is only slightly dependent on heterogeneity complexity. Furthermore, we also show that the energy spectra of the proton fluence downstream of various heterogeneity volumes are well correlated with the Bragg peak distal fall-off widths. Based on this correlation, a novel method for predicting distal fall-offs is suggested. This method is tested for three clinical setups of a voxelized model of a human head based on computer tomography data. Results are within 3% of the distal fall-off values obtained using Monte Carlo simulations.Keywords
This publication has 12 references indexed in Scilit:
- Quantifying lateral tissue heterogeneities in hadron therapyMedical Physics, 2007
- Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non–small-cell lung cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Monte Carlo simulation of a protontherapy platform devoted to ocular melanomaMedical Physics, 2005
- Monte Carlo dose calculations for spot scanned proton therapyPhysics in Medicine & Biology, 2005
- Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous mediaPhysics in Medicine & Biology, 2002
- Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculationPhysics in Medicine & Biology, 1999
- A technique for calculating range spectra of charged particle beams distal to thick inhomogeneitiesMedical Physics, 1998
- Degradation of the Bragg peak due to inhomogeneitiesPhysics in Medicine & Biology, 1986
- Intranuclear-Cascade Calculation of the Secondary Nucleon Spectra from Nucleon-Nucleus Interactions in the Energy Range 340 to 2900 MeV and Comparisons with ExperimentPhysical Review B, 1969
- Low-Energy Intranuclear Cascade CalculationPhysical Review B, 1963