A deflectable guiding catheter for real‐time MRI‐guided interventions
Open Access
- 29 November 2011
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 35 (4) , 908-915
Abstract
Purpose: To design a deflectable guiding catheter that omits long metallic components yet preserves mechanical properties to facilitate therapeutic interventional MRI procedures.Materials and Methods: The catheter shaft incorporated Kevlar braiding. A 180° deflection was attained with a 5‐cm nitinol slotted tube, a nitinol spring, and a Kevlar pull string. We tested three designs: passive, passive incorporating an inductively coupled coil, and active receiver. We characterized mechanical properties, MRI properties, RF induced heating, and in vivo performance in swine.Results: Torque and tip deflection force were satisfactory. Representative procedures included hepatic and azygos vein access, laser cardiac septostomy, and atrial septal defect crossing. Visualization was best in the active configuration, delineating profile and tip orientation. The passive configuration could be used in tandem with an active guidewire to overcome its limited conspicuity. There was no RF‐induced heating in all configurations under expected use conditions in vitro and in vivo.Conclusion: Kevlar and short nitinol component substitutions preserved mechanical properties. The active design offered the best visibility and usability but reintroduced metal conductors. We describe versatile deflectable guiding catheters with a 0.057” lumen for interventional MRI catheterization. Implementations are feasible using active, inductive, and passive visualization strategies to suit application requirements. J. Magn. Reson. Imaging 2012;35:908–915.Keywords
This publication has 14 references indexed in Scilit:
- Magnetic Resonance–Guided Cardiac Interventions Using Magnetic Resonance–Compatible DevicesCirculation: Cardiovascular Interventions, 2010
- Interventional MRI: Tapering improves the distal sensitivity of the loopless antennaMagnetic Resonance in Medicine, 2010
- Interventional Cardiovascular Magnetic Resonance ImagingJACC: Cardiovascular Imaging, 2009
- Interventional cardiovascular magnetic resonance: still tantalizingJournal of Cardiovascular Magnetic Resonance, 2008
- Interventional cardiovascular procedures guided by real‐time MR imaging: An interactive interface using multiple slices, adaptive projection modes and live 3D renderingsJournal of Magnetic Resonance Imaging, 2007
- Minimizing RF heating of conducting wires in MRIMagnetic Resonance in Medicine, 2007
- Magnetically‐assisted remote control (MARC) steering of endovascular catheters for interventional MRI: A model for deflection and design implicationsMedical Physics, 2007
- MR-Guided Endovascular Interventions: Device Visualization, Tracking, Navigation, Clinical Applications, and Safety AspectsMagnetic Resonance Imaging Clinics of North America, 2005
- MR‐trackable intramyocardial injection catheterMagnetic Resonance in Medicine, 2004
- Remote control of catheter tip deflection: An opportunity for interventional MRIMagnetic Resonance in Medicine, 2002