Protein adsorption and platelet adhesion of polysulfone membrane immobilized with chitosan and heparin conjugate
Authors:
- 17 February 2003
- journal article
- research article
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 14 (2) , 103-113
Abstract
Polysulfone (PSF) membranes were treated with ozone to introduce peroxides, and then grafted with either acrylic acid or chitosan, followed by the immobilization of heparin. The effect of spacer arm on blood compatibility was investigated using three chitosans of different molecular weight [1170 (water soluble), 160 000, and 400 000] and similar degrees of deacetylation (75%). The hydrophilicity was evaluated by measuring the contact angle of water. Blood compatibility was evaluated using the activated partial thromboplastin time (APTT) as well as the adhesion of platelets. The protein affinity was determined by the absorption of human serum albumin (HSA) and human plasma fibrinogen (HPF). The results show that by the coupling of chitosan, the amount of heparin immobilized can be increased by four times. Water contact angle (from 78 ° to 41 °) decreased with the increase of the amount of heparin immobilized, showing increased wettability. The heparinized PSF membrane showed longer APTT and decreasing platelet adhesion, compared to that of unmodified PSF membrane. The adsorption of HSA and HPF were reduced to 17 and 6%, respectively. This suggests that longer spacer binding to heparin can increase the opportunity of anti‐coagulation on contacting blood. These results demonstrated that the hydrophilicity and blood compatibility of PSF membrane could be improved by chitosan and heparin conjugate. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Immobilization of DNA onto a polymer support and its potentiality as immunoadsorbentBiotechnology and Bioengineering, 2000
- Surface modification of chitosan membranes by complexation-interpenetration of anionic polysaccharides for improved blood compatibility in hemodialysisJournal of Biomaterials Science, Polymer Edition, 1997
- Evaluation of an epoxy-fixed biological patch with ionically bound heparin as a pericardial substituteBiomaterials, 1996
- Ozone‐induced graft polymerization onto polymer surfaceJournal of Polymer Science Part A: Polymer Chemistry, 1993
- Binding Kinetics of Thrombin and Antithrombin III with Immobilized Heparin Using a SpacerASAIO Journal, 1992
- Surface‐modified polysulfone hollow fibers. II. Fibers having CH2CH2CH2SO3− segments and immersed in HCI solutionJournal of Applied Polymer Science, 1990
- Preparation and surface characterization of PEO-grafted and heparin-immobilized polyurethanesJournal of Biomedical Materials Research, 1989
- Inactivation of thrombin in heparin-PVA coated tubesJournal of Biomaterials Science, Polymer Edition, 1989
- Heparin immobilization onto segmented polyurethaneurea surfaces—effect of hydrophilic spacersJournal of Biomedical Materials Research, 1988
- Inactivation of thrombin by antithrombin III on a heparinized biomaterialThrombosis Research, 1980