Automatic Removal of Physiological Artifacts in OPM-MEG: A Framework of Channel Attention Mechanism Based on Magnetic Reference Signal
Open Access
- 9 October 2025
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 15 (10) , 680
Abstract
The high spatiotemporal resolution of optically pumped magnetometers (OPMs) makes them an essential tool for functional brain imaging, enabling accurate recordings of neuronal activity. However, physiological signals such as eye blinks and cardiac activity overlap with neural magnetic signals in the frequency domain, resulting in contamination and creating challenges for the observation of brain activity and the study of neurological disorders. To address this problem, an automatic physiological artifact removal method based on OPM magnetic reference signals and a channel attention mechanism is proposed. The randomized dependence coefficient (RDC) is employed to evaluate the correlation between independent components and reference signals, enabling reliable recognition of artifact components and the construction of training and testing datasets. A channel attention mechanism is subsequently introduced, which fuses features from global average pooling (GAP) and global max pooling (GMP) layers through convolution to establish a data-driven automatic recognition model. The backbone network is further optimized to enhance performance. Experimental results demonstrate a strong correlation between the magnetic reference signals and artifact components, confirming the reliability of magnetic signals as artifact references for OPM-MEG. The proposed model achieves an artifact recognition accuracy of 98.52% and a macro-average score of 98.15%. After artifact removal, both the event-related field (ERF) responses and the signal-to-noise ratio (SNR) are significantly improved. Leveraging the flexible and modular characteristics of OPM-MEG, this study introduces an artifact recognition framework that integrates magnetic reference signals with an attention mechanism. This approach enables highly accurate automatic recognition and removal of OPM-MEG artifacts, paving the way for real-time, automated data analysis in both scientific research and clinical applications.Keywords
Funding Information
- Innovation Program for Quantum Science and Technology, Hefei National Laboratory (2021ZD0300503, 2022ZLGX03)
- Key R&D Program of Shandong Province (2021ZD0300503, 2022ZLGX03)
This publication has 39 references indexed in Scilit:
- Design of locally arranged sensor arrays in wearable OPM-MEG based on sensor volume constraintsMeasurement, 2024
- Infant brain imaging using magnetoencephalography: Challenges, solutions, and best practicesHuman Brain Mapping, 2022
- Usage of drip drops as stimuli in an auditory P300 BCI paradigmCognitive Neurodynamics, 2017
- Removing Cardiac Artefacts in Magnetoencephalography with Resampled Moving Average SubtractionBrain Topography, 2016
- Ocular and cardiac artifact rejection for real-time analysis in MEGJournal of Neuroscience Methods, 2014
- ICA-based artifact correction improves spatial localization of adaptive spatial filters in MEGNeuroImage, 2013
- Good practice for conducting and reporting MEG researchNeuroImage, 2013
- Comparison of the Properties of EEG and MEG in Detecting the Electric Activity of the BrainBrain Topography, 2011
- Magnetoencephalographic artifact identification and automatic removal based on independent component analysis and categorization approachesJournal of Neuroscience Methods, 2006
- Canonical ridge and econometrics of joint productionJournal of Econometrics, 1976