Industrial Robot Calibration Using a Virtual Linear Constraint
Authors:
Open Access
- 1 January 2012
- journal article
- Published by Walter de Gruyter GmbH in International Journal on Smart Sensing and Intelligent Systems
- Vol. 5 (4) , 987-1001
Abstract
This paper proposes a systematic method to identify the joint zero offset of industrial robot. Small offset always exist in robot joint, which affect the precision in kinematic equations leading to calculate wrong joint angle values. To solve these problems, the proposed method employs a portable dual Position Sensitive Detector (PSD) device and a focusable laser point (FLP). The portable dual PSD device comprises two fixed PSDs tilted in an angle to reflect the laser line from one PSD to another. The FLP, attached to the robot end-effector, aims at both centers of the two PSDs at the same time, effectively creating a virtual linear constraint for the robot end-effector. As a result, small variations in position and orientation of the end-effector are magnified on the laser spot’s location at the PSD’s surface. Hence, the resolution of measuring the position and orientation of the end-effector is improved due to the high precision feedback of the PSD, increasing the accuracy of joint angle measurements that are required to calibrate the robot. From the easily measured joint angle readings, and an identification model, the joint zero offset of industrial robot is calibrated. The effectiveness and accuracy of the method are verified using both simulations and real experiments on an IRB120 robot.Keywords
This publication has 17 references indexed in Scilit:
- Absolute calibration of an ABB IRB 1600 robot using a laser trackerRobotics and Computer-Integrated Manufacturing, 2013
- Training Data Compression Algorithms and Reliability in Large Wireless Sensor NetworksInternational Journal on Smart Sensing and Intelligent Systems, 2008
- An Automated Method to Calibrate Industrial Robots Using a Virtual Closed Kinematic ChainIEEE Transactions on Robotics, 2007
- Experimental results on kinematic calibration of parallel manipulators using a partial pose measurement deviceIEEE Transactions on Robotics, 2006
- Calibration of a measuring robot: Experimental results on a 5 DOF structureJournal of Robotic Systems, 2001
- The Calibration Index and Taxonomy for Robot Kinematic Calibration MethodsThe International Journal of Robotics Research, 1996
- Robot calibration using an automatic theodoliteThe International Journal of Advanced Manufacturing Technology, 1994
- Full-pose calibration of a robot manipulator using a coordinate-measuring machineThe International Journal of Advanced Manufacturing Technology, 1993
- Determination of Optimal Measurement Configurations for Robot Calibration Based on Observability MeasureThe International Journal of Robotics Research, 1991
- Automatic laser tracking interferometer system for robot metrologyPrecision Engineering, 1986