Dosimetry close to an HDR source using N‐vinylpyrrolidone based polymer gels and magnetic resonance imaging
Authors:
- P. PapagiannisPPP. Papagiannis
- E. PappasEPE. Pappas
- P. KipourosPKP. Kipouros
- A. AngelopoulosAAA. Angelopoulos
- L. SakelliouLSL. Sakelliou
- P. BarasPBP. Baras
- P. KaraiskosPKP. Karaiskos
- I. SeimenisISI. Seimenis
- P. SandilosPSP. Sandilos
- D. BaltasDBD. Baltas
- 6 July 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (7) , 1416-1426
Abstract
In this work, the utilization of polymer gel–MRI dosimetry for measurements at distances relevant to clinical brachytherapy and intravascular applications [i.e., in the mm range, where steep three‐dimensional (3‐D) dose gradients exist] is investigated using N‐vinylpyrrolidone‐based gels. Transverse axis radial dose distributions, dose distributions parallel to the source axis, and 2‐D dose distributions around the commonly used microSelectron HDR source are measured for single source dwell position irradiations. Experimental results are found in good agreement with verified Monte Carlo calculations, even for distances less than 3 mm from the source. The effect of various MRI parameters, such as slice thickness, slice mispositioning, and in‐plane resolution, on the accuracy of the method is also investigated. Possible limitations of the method are discussed, and its' overall potential in brachytherapy dosimetry is evaluated. Experimental 2‐D dose distributions for an intravascular application following the Paris irradiation protocol are compared to corresponding commercial treatment planning system calculations. Results suggest that polymer gel–MRI dosimetry is capable of experimentally verifying dose distributions in relevant clinical intravascular applications.Keywords
This publication has 32 references indexed in Scilit:
- Limitations of the point and line source approximations for the determination of geometry factors around brachytherapy sourcesMedical Physics, 2000
- Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapyMedical Physics, 1999
- A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy sourceMedical Physics, 1999
- Monte Carlo‐aided dosimetry of a new high dose‐rate brachytherapy sourceMedical Physics, 1998
- Monte Carlo and TLD dosimetry of an high dose‐rate brachytherapy sourceMedical Physics, 1998
- Anisotropy of an high dose rate source measured with a miniature ionization chamberMedical Physics, 1997
- TLD, diode and Monte Carlo dosimetry of an192Ir source for high dose-rate brachytherapyPhysics in Medicine & Biology, 1995
- Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeterPhysics in Medicine & Biology, 1994
- NMR relaxation enhancement in gels polymerized and cross-linked by ionizing radiation: A new approach to 3D dosimetry by MRIMagnetic Resonance Imaging, 1993
- Dose rate distribution around60Co,137Cs,198Au,192Ir,241Am,125I (models 6702 and 6711) brachytherapy sources and the nuclide99TcmPhysics in Medicine & Biology, 1992