Comparison between the PD Characteristics of g3 and Dry Air for Gas-Insulated Switchgears
Open Access
- 25 September 2022
- Vol. 15 (19) , 7043
Abstract
This paper presents a comparison between the partial discharge (PD) characteristics of g3 and dry air for gas-insulated switchgears. PD signals were measured with a conventional method according to IEC 60270 and an ultra-high frequency (UHF) method. The partial discharge inception voltages (PDIVs) of g3 and dry air are about 74% to 84% and 58% to 72%, respectively, in the protrusion on conductor (POC) system, and 90% to 96% and 80% to 93%, respectively, in the free moving particle (FMP) system, depending on the gas pressure of 0.1 MPa to 0.5 MPa. The single PD pulse in time and frequency domains are not distinguished according to gas type. The PRPD patterns have different phase angles depending on the gas type in the POC, while the phase angle is 0–360° in the FMP, regardless of the gas type. Lastly, the correlation was analyzed, showing that the output voltage in mV of the UHF sensor increases linearly in accordance with the apparent discharge in pC, regardless of the gas type. The experimental results in this paper are important as a fundamental database for the application of UHF monitoring systems in an eco-friendly GIS.Keywords
Funding Information
- Ministry of Education and National Research Foundation of Korea (1345356149)
This publication has 25 references indexed in Scilit:
- Effective ionization coefficients and limiting field strength of fluoronitriles-CO2 mixturesIEEE Transactions on Dielectrics and Electrical Insulation, 2017
- Fluoronitriles/CO2 gas mixture as promising substitute to SF6 for insulation in high voltage applicationsIEEE Transactions on Dielectrics and Electrical Insulation, 2016
- CF3I Gas Mixtures: Breakdown Characteristics and Potential for Electrical InsulationIEEE Transactions on Power Delivery, 2016
- Electron swarm parameters of the hydrofluoroolefine HFO1234zePlasma Sources Science and Technology, 2016
- Green Gas to Replace SF6 in Electrical GridsIEEE Power and Energy Magazine, 2016
- ${\rm CO}_{2}$ as an Arc Interruption Medium in Gas Circuit BreakersIEEE Transactions on Plasma Science, 2013
- Impulse Breakdown Behaviors of Dry Air as an Alternative Insulation Gas for SF6Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2011
- Recent trend and future perspectives in electrical insulation techniques in relation to sulfur hexafluoride (SF6) substitutes for high voltage electric power equipmentIEEE Electrical Insulation Magazine, 2011
- Fundamental Insulation Characteristics of Air, N2, CO2, N2/O2 and SF6/N2 Mixed GasesIEEJ Transactions on Power and Energy, 2005
- Electron transport and swarm parameters in CO2and its mixtures with SF6Journal of Physics D: Applied Physics, 2002