Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering
- 11 December 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (10) , 4085-4093
Abstract
Electrocardiography (ECG) measurements are essential components in clinical diagnosis and monitoring. Conventional ECG measurements produce discomfort to the patients due to the use of gel and direct skin contact. Capacitive electrodes can measure ECG signals through an isolation layer; they are especially suitable for long-term ambulatory monitoring. However, capacitive ECG measurements are severely affected by motion artifacts (MAs) due to variable coupling distance. Adaptive filtering has been widely used for MA reduction in ECG measurements. Unfortunately, a reference signal recorded by additional sensors is required for the existing adaptive-filtering methods, limiting their applicability in ambulatory settings. In this paper on capacitive ECG recordings, a novel adaptive-filtering method is proposed for MA removal, where the reference signal is extracted from the power-line interference (PLI). PLI is particularly evident in a capacitive ECG due to unbalanced coupling capacitance. Along with MAs, electrode movement causes variations in the PLI amplitude. By demodulating the PLI, a reference signal reflecting variations in the coupling capacitance can be extracted for adaptive MA removal. The proposed method was evaluated both by simulations and real data and compared with the acceleration-based adaptive-filtering method. Comparable or higher ECG signal-to-noise ratio was achieved by the proposed method with a computational cost of 79 μs/iteration, indicating effective MA removal. The proposed method may, therefore, lead to improved analysis of capacitive ECG signals in ambulatory settings.Keywords
Funding Information
- Stichting voor de Technische Wetenschappen
- Applied and Engineering Sciences
- NWO Domain
This publication has 29 references indexed in Scilit:
- Unobtrusive ECG monitoring in the NICU using a capacitive sensing arrayPhysiological Measurement, 2014
- An adaptive filtering approach for electrocardiogram (ECG) signal noise reduction using neural networksNeurocomputing, 2013
- A Configurable and Low-Power Mixed Signal SoC for Portable ECG Monitoring ApplicationsIEEE Transactions on Biomedical Circuits and Systems, 2013
- A comprehensive survey of wearable and wireless ECG monitoring systems for older adultsMedical & Biological Engineering & Computing, 2013
- Low-complexity R-peak detection for ambulatory fetal monitoringPhysiological Measurement, 2012
- First clinical evaluation of a novel capacitive ECG system in patients with acute myocardial infarctionClinical Research in Cardiology, 2011
- Insulating electrodes: a review on biopotential front ends for dielectric skin–electrode interfacesPhysiological Measurement, 2010
- An Improved Adaptive Power Line Interference Canceller for ElectrocardiographyIEEE Transactions on Biomedical Engineering, 2006
- ECG measurement on a chair without conductive contactIEEE Transactions on Biomedical Engineering, 2006
- High-quality recording of bioelectric eventsMedical & Biological Engineering & Computing, 1990