Adjunctive Balloon Postdilatation after Stent Deployment: Is It Still Necessary with Drug‐Eluting Stents?
- 15 February 2006
- journal article
- review article
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 19 (1) , 43-50
Abstract
Deployment of bare metal stents (BMS) with current stent delivery systems is often associated with suboptimal stent expansion. Adjunctive postdilatation with noncompliant balloons has improved stent expansion with BMS and has been associated with less need for target vessel revascularization (TVR). Drug‐eluting stents (DES) have proven highly effective in reducing restenosis and TVR and are now being used in the great majority of percutaneous coronary interventions. Because of the very low rates of TVR with DES, many operators have felt that postdilatation may no longer be necessary. In this review, we present data showing that stent expansion of DES (like BMS) using current stent delivery systems is frequently suboptimal. Furthermore, smaller mimimal stent area (MSA) and stent underexpansion following deployment of DES are strong predictors of stent thrombosis and TVR. Adjunctive postdilatation with noncompliant balloons can increase MSA and decrease the frequency of suboptimal stent deployment and potentially can reduce the frequency of stent thrombosis and TVR. Despite the lack of evidence from randomized clinical trials, we believe the observational data support the use of adjunctive balloon postdilatation following deployment of DES in the great majority of patients.Keywords
This publication has 30 references indexed in Scilit:
- Intravascular Ultrasonic Assessment of Stent Diameters Derived from Manufacturer’s Compliance ChartsThe American Journal of Cardiology, 2005
- Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantationJACC, 2005
- Nonuniform Strut Distribution Correlates With More Neointimal Hyperplasia After Sirolimus-Eluting Stent ImplantationCirculation, 2004
- Usefulness of high-pressure post-dilatation to optimize deployment of drug-eluting stents for the treatment of diffuse in-stent coronary restenosisThe American Journal of Cardiology, 2004
- Comparison of once daily versus twice daily oral nitrates in stable angina pectorisThe American Journal of Cardiology, 2004
- Sirolimus-Eluting Stents versus Standard Stents in Patients with Stenosis in a Native Coronary ArteryNew England Journal of Medicine, 2003
- Is adjunctive balloon postdilatation necessary after coronary stent deployment? Final results from the POSTIT trialCatheterization and Cardiovascular Interventions, 2003
- Intravascular Ultrasound Guidance Improves Angiographic and Clinical Outcome of Stent Implantation for Long Coronary Artery StenosesCirculation, 2003
- ACCIS2001 angiography & interventional cardiologyJACC, 2001
- Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis?The American Journal of Cardiology, 1999