Reduction in Intraoperative Bacterial Contamination of Peripheral Intravenous Tubing Through the Use of a Passive Catheter Care System
Authors:
- Randy W. LoftusRLRandy W. Loftus
- Bryan S. BrindeiroBBBryan S. Brindeiro
- David P. KispertDKDavid P. Kispert
- Hetal M. PatelHPHetal M. Patel
- Matthew D. KoffMKMatthew D. Koff
- Jens T. JensenJJJens T. Jensen
- Thomas M. DoddsTDThomas M. Dodds
- Mark P. YeagerMYMark P. Yeager
- Kathryn L. RuoffKRKathryn L. Ruoff
- John D. GallagherJGJohn D. Gallagher
- Michael L. BeachMBMichael L. Beach
- Jeremiah R. BrownJBJeremiah R. Brown
- 1 December 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 115 (6) , 1315-1323
Abstract
Bacterial contamination of intravascular devices has been associated with increased morbidity and mortality in various hospital settings, including the perioperative environment. Catheter hub disinfection has been shown in an ex vivo model to attenuate intraoperative injection of bacterial organisms originating from the anesthesia provider’s hands, providing the impetus for improvement in intraoperative disinfection techniques and compliance. In the current study, we investigated the clinical effectiveness of a new, passive catheter care station in reducing the incidence of bacterial contamination of open lumen patient IV stopcock sets. The secondary aim was to evaluate the impact of this novel intervention on the combined incidence of 30-day postoperative infections and IV catheter–associated phlebitis. Five hundred ninety-four operating room environments were randomized by a computer-generated list to receive either a novel catheter care bundle (HubScrub and DOCit) or standard caps in conjunction with a sterile, conventional open lumen 3-way stopcock set (24 inch with 3-gang 4-way and T-Connector). Patients underwent general anesthesia according to usual practice and were followed prospectively for 30 postoperative days to identify the development of health care–associated infections (HCAIs) and/or phlebitis. The primary outcome was intraoperative bacterial contamination of the primary stopcock set used by the anesthesia provider(s). The secondary outcome was the combined incidence of 30-day postoperative infections and phlebitis. Five hundred seventy-two operating rooms were included in the final analysis. Study groups were comparable with no significant differences in patient, provider, anesthetic, or procedural characteristics. The catheter care station reduced the incidence of primary stopcock lumen contamination compared with standard caps (odds ratio [OR] 0.79, 95% confidence interval [CI] 0.63–0.98, P = 0.034) and was associated with a reduction in the combined incidence of HCAIs and IV catheter–associated phlebitis with and without adjustment for patient and procedural covariates (ORadjusted 0.589, 95% CI 0.353–0.984, P = 0.040). The risk-adjusted number needed to treat to eliminate 1 case of lumen contamination was 9 (95% CI 3.4–13.5) patients, whereas the risk-adjusted number needed to treat to eliminate 1 case of HCAI/catheter-associated phlebitis was 17 (95% CI 11.8–17.9) patients. Intraoperative use of a passive catheter care station significantly reduced open lumen bacterial contamination and the combined incidence of 30-day postoperative infections and phlebitis.Keywords
This publication has 16 references indexed in Scilit:
- Multiple Reservoirs Contribute to Intraoperative Bacterial TransmissionAnesthesia & Analgesia, 2012
- Hand Contamination of Anesthesia Providers Is an Important Risk Factor for Intraoperative Bacterial TransmissionAnesthesia & Analgesia, 2011
- Transmission of Pathogenic Bacterial Organisms in the Anesthesia Work AreaAnesthesiology, 2008
- Efficacy of three different valve systems of needle-free closed connectors in avoiding access of microorganisms to endovascular catheters after incorrect handling*Critical Care Medicine, 2008
- Catheter-related Bacteremia and Multidrug-resistant Acinetobacter lwoffiiEmerging Infectious Diseases, 2007
- The Risk of Bloodstream Infection in Adults With Different Intravascular Devices: A Systematic Review of 200 Published Prospective StudiesMayo Clinic Proceedings, 2006
- Colonization of the medial lumen is a risk factor for catheter-related bloodstream infectionIntensive Care Medicine, 2006
- The micro-organism responsible for central venous catheter related bloodstream infection depends on catheter siteIntensive Care Medicine, 2006
- Rates of infection for single-lumen versus multilumen central venous catheters: A meta-analysisCritical Care Medicine, 2003
- Infectious complications among patients receiving home intravenous therapy with peripheral, central, or peripherally placed central venous cathetersThe American Journal of Medicine, 1991