Is there more than meets the eye in PSMA imaging in prostate cancer with PET/MRI? Looking closer at uptake time, correlation with PSA and Gleason score
Open Access
- 17 April 2023
- journal article
- research article
- Published by Springer Nature in European Journal of Hybrid Imaging
- Vol. 7 (1) , 1-12
Abstract
Background: In patients with increasing PSA and suspicion for prostate cancer, but previous negative biopsies, PET/MRI is used to test for tumours and target potential following biopsy. We aimed to determine different PSMA PET timing effects on signal kinetics and test its correlation with the patients’ PSA and Gleason scores (GS). Methods: A total of 100 patients were examined for 900 s using PET/MRI approximately 1–2 h p.i. depending on the tracer used (68Ga-PSMA-11, 18F-PSMA-1007 or 18F-rhPSMA7). The scans were reconstructed in static and dynamic mode (6 equal frames capturing “late” PSMA dynamics). TACs were computed for detected lesions as well as linear regression plots against time for static (SUV) and dynamic (SUV, SUL, and percent injected dose per gram) parameters. All computed trends were tested for correlation with PSA and GS. Results: Static and dynamic scans allowed unchanged lesion detection despite the difference in statistics. For all tracers, the lesions in the pelvic lymph nodes and bones had a mostly negative activity concentration trend (78% and 68%, resp.), while a mostly positive, stronger trend was found for the lesions in the prostate and prostatic fossa following RPE (84% and 83%, resp.). In case of 68Ga-PSMA-11, a strong negative (Rmin = − 0.62, Rmax = − 0.73) correlation was found between the dynamic parameters and the PSA. 18F-PSMA-1007 dynamic data showed no correlation with PSA, while for 18F-rhPSMA7 dynamic data, it was consistently low positive (Rmin = 0.29, Rmax = 0.33). All tracers showed only moderate correlation against GS (Rmin = 0.41, Rmax = 0.48). The static parameters showed weak correlation with PSA (Rmin = 0.24, Rmax = 0.36) and no correlation with GS. Conclusion: “Late” dynamic PSMA data provided additional insight into the PSMA kinetics. While a stable moderate correlation was found between the PSMA kinetics in pelvic lesions and GS, a significantly variable correlation with the PSA values was shown depending on the radiotracer used, the highest being consistently for 68Ga-PSMA-11. We reason that with such late dynamics, the PSMA kinetics are relatively stable and imaging could even take place at earlier time points as is now in the clinical routine.Keywords
All Related Versions
Funding Information
- Deutsche Forschungsgemeinschaft (DFG) grant within Research Training Group GRK 2274
- Klinikum rechts der Isar der Technischen Universität München
This publication has 20 references indexed in Scilit:
- Multiple Time-Point 68Ga-PSMA I&T PET/CT for Characterization of Primary Prostate CancerClinical Nuclear Medicine, 2017
- 68Ga-PSMA PET/CT: Joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0European Journal of Nuclear Medicine and Molecular Imaging, 2017
- 68Ga-PSMA-11 PET/CT in primary staging of prostate cancer: PSA and Gleason score predict the intensity of tracer accumulation in the primary tumourEuropean Journal of Nuclear Medicine and Molecular Imaging, 2017
- Early dynamic imaging in 68Ga- PSMA-11 PET/CT allows discrimination of urinary bladder activity and prostate cancer lesionsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2016
- Simultaneous 68Ga-PSMA HBED-CC PET/MRI Improves the Localization of Primary Prostate CancerEuropean Urology, 2016
- Gleason score 5 + 3 = 8 prostate cancer: much more like Gleason score 9?BJU International, 2015
- Comparison of PET imaging with a 68Ga-labelled PSMA ligand and 18F-choline-based PET/CT for the diagnosis of recurrent prostate cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- PET Imaging in Prostate Cancer: Focus on Prostate-Specific Membrane AntigenCurrent Topics in Medicinal Chemistry, 2013
- Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR ScannerJournal of Nuclear Medicine, 2011
- Prostate Cancer Specific Mortality and Gleason 7 Disease Differences in Prostate Cancer Outcomes Between Cases With Gleason 4 + 3 and Gleason 3 + 4 Tumors in a Population Based CohortJournal of Urology, 2009