Influence of the anatomic characteristics of the pulmonary vein ostium, the learning curve, and the use of a steerable sheath on success of pulmonary vein isolation with a novel multielectrode ablation catheter
Authors:
- A. GrosseAGA. Grosse
- J. Christoph GellerJGJ. Christoph Geller
Open Access
- 23 October 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 14 (3) , 331-340
Abstract
Anatomic variability of the pulmonary vein (PV) ostium may adversely affect isolation rates with the circular fixed-size pulmonary vein ablation catheter (PVAC). We wanted to assess the influence on PV isolation rates of anatomic characteristics of the ostium, increasing experience of four different operators, and additional use of a steerable sheath. In the first 190 patients (pts) undergoing PVAC ablation, minimum/maximum diameter, area and shape of the PV ostia, and the length of a common ostium were analysed from computed tomography 3D reconstructions of the left atrium and related to isolation rates. In addition, a comparison was drawn between pts at the beginning and after completion (isolation of all PVs in ≥85% of pts) of the learning curve, and the effect of a steerable sheath was assessed. Pulmonary vein isolation was achieved with the PVAC alone in 85% of pts and in 94% of veins after a median procedure and ablation time of 154 [interquartile ranges (IQR): 120, 200] and 51 (IQR: 38, 70) min. An increase in isolation rates was observed after the first 60 pts (73 vs. 90% of pts; P< 0.01; 88 vs. 96% of PVs; P< 0.001), coincident with routine use of a steerable sheath. Anatomic characteristics (larger minimum diameter and area) identified unsuccessful isolation only of the left inferior PV at the beginning of the learning curve. Pulmonary vein isolation rates using this catheter are high. Anatomic variability of PV ostia modestly affects PV isolation rates. Standard use of a steerable sheath plays a major role in increasing isolation rates and overcoming ‘difficult’ anatomies.Keywords
This publication has 32 references indexed in Scilit:
- Catheter Ablation for Paroxysmal Atrial Fibrillation: A Randomized Comparison between Multielectrode Catheter and Point-by-Point AblationPacing and Clinical Electrophysiology, 2010
- Pulmonary vein isolation with the 30 and 35 mm high-density mesh ablatorEP Europace, 2010
- Voltage mapping and pacing to assess the level of pulmonary venous isolation achieved with a novel circular multielectrode ablation catheterEP Europace, 2010
- Results of Short‐Term and Long‐Term Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation Using Duty‐Cycled Bipolar and Unipolar Radiofrequency EnergyJournal of Cardiovascular Electrophysiology, 2010
- Mapping and Isolation of the Pulmonary Veins Using the PVAC CatheterPacing and Clinical Electrophysiology, 2010
- Characterization of In Vitro and In Vivo Lesions Made by a Novel Multichannel Ablation Generator and a Circumlinear Decapolar Ablation CatheterJournal of Cardiovascular Electrophysiology, 2009
- Safe and Rapid Isolation of Pulmonary Veins Using a Novel Circular Ablation Catheter and Duty‐Cycled RF GeneratorJournal of Cardiovascular Electrophysiology, 2009
- Routine echocardiography after radiofrequency ablation: to flog a dead horse?EP Europace, 2008
- The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre studyEuropean Heart Journal, 2008
- External and Endoluminal Analysis of Left Atrial Anatomy and the Pulmonary Veins in Three‐Dimensional Reconstructions of Magnetic Resonance Angiography: The Full Insight from InsideJournal of Cardiovascular Electrophysiology, 2006