Abstract
Background and aims The main limitation of plastic stents is the relatively short stent patency due to occlusion. We designed enteral extended biliary stents with lengths of 26 cm (EEBS-26 cm) and 30 cm (EEBS-30 cm) to prolong stent patency. This study aimed to compare patency among EEBS-26 cm, EEBS-30 cm, and conventional plastic biliary stent (CPBS). Methods A single-center prospective randomized controlled study was conducted. Eligible patients were randomized into the EEBS-26 cm, EEBS-30 cm, and CPBS groups, respectively. All patients were followed up every 3 months until stent occlusion, patient death, or at 12-month follow-up. The primary outcome was stent patency. The secondary outcomes included stent occlusion rate, patient survival, mortality, the rate of technical success, and adverse events. Results Totally 117 patients were randomized into the three groups. There were no significant differences among the three groups in technical success rate, hospital stay, mortality, patient survival, and adverse events (P = 1.000, 0.553, 0.965, 0.302, and 0.427, respectively). Median stent patency durations in the EEBS-26 cm, EEBS-30 cm, and CPBS groups were 156.0 (95% CI 81.6–230.4) days, 81.0 (95% CI 67.9–94.1) days, and 68.0 (95% CI 20.0–116.0) days, respectively (P = 0.002). The EEBS-26 cm group had longer stent patency compared with the CPBS (P = 0.007) and EEBS-30 cm (P < 0.001) groups. The EEBS-26 cm group had lower stent occlusion rates compared with the other groups at 6 months (48.1% vs. 90.5% vs. 82.8%, P = 0.001) and 9 months (75.0% vs. 100.0% vs. 92.9%, P = 0.022). Conclusion EEBS-26 cm has prolonged stent patency and is safe and effective for the alleviation of unresectable extrahepatic malignant biliary obstruction. Graphical abstract
Funding Information
  • National Natural Science Foundation of China (82070653)

This publication has 41 references indexed in Scilit: