Purpose: To assess the impact of the different post‐processing options in the calibration of arterial spin labeling (ASL) data on perfusion quantification and its reproducibility.Theory and Methods: Absolute quantification of perfusion measurements is one of the promises of ASL techniques. However, it is highly dependent on a calibration procedure that involves a complex processing pipeline for which no standardized procedure has been fully established. In this work, we systematically compare the main ASL calibration methods as well as various post‐processing calibration options, using 2 data sets acquired with the most common sequences, pulsed ASL and pseudo‐continuous ASL.Results: Significant and sometimes large discrepancies in ASL perfusion quantification were obtained when using different post‐processing calibration options. Nevertheless, when using a set of theoretically based and carefully chosen options, only small differences were observed for both reference tissue and voxelwise methods. The voxelwise and white matter reference tissue methods were less sensitive to post‐processing options than the cerebrospinal fluid reference tissue method. However, white matter reference tissue calibration also produced poorer reproducibility results. Moreover, it may also not be an appropriate reference in case of white matter pathology.Conclusion: Poor post‐processing calibration options can lead to large errors in perfusion quantification, and a complete description of the calibration procedure should therefore be reported in ASL studies. Overall, our results further support the voxelwise calibration method proposed by the ASL white paper, particularly given the advantage of being relatively simple to implement and intrinsically correcting for the coil sensitivity profile.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/P012361/1)
- Wellcome Trust (203139/Z/16/Z)
- Fundação para a Ciência e a Tecnologia (PD/BD/135114/2017, PTDC/BBB‐IMG/2137/2012, UID/EEA/50009/2019)
This publication has 36 references indexed in Scilit:
- Cerebral Blood Flow Quantification Using Vessel-Encoded Arterial Spin LabelingJournal of Cerebral Blood Flow & Metabolism, 2013
- Modeling dispersion in arterial spin labeling: Validation using dynamic angiographic measurementsMagnetic Resonance in Medicine, 2012
- Localization of the hand motor area by arterial spin labeling and blood oxygen level-dependent functional magnetic resonance imagingHuman Brain Mapping, 2011
- Sensitivity calibration with a uniform magnetization image to improve arterial spin labeling perfusion quantificationMagnetic Resonance in Medicine, 2011
- Test–retest reliability of arterial spin labeling with common labeling strategiesJournal of Magnetic Resonance Imaging, 2011
- Intra- and Multicenter Reproducibility of Pulsed, Continuous and Pseudo-Continuous Arterial Spin Labeling Methods for Measuring Cerebral PerfusionJournal of Cerebral Blood Flow & Metabolism, 2011
- Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3TNeuroImage, 2011
- The QUASAR reproducibility study, Part II: Results from a multi-center Arterial Spin Labeling test–retest studyNeuroImage, 2010
- Quantitative perfusion measurements using pulsed arterial spin labeling: Effects of large region‐of‐interest analysisJournal of Magnetic Resonance Imaging, 2005
- Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithmIEEE Transactions on Medical Imaging, 2001