3E (Energy–Exergy–Environmental) Performance Analysis and Optimization of Seawater Shower Cooling Tower for Central Air Conditioning Systems
Open Access
Abstract
The thermodynamic, exergy and carbon reduction potential of seawater shower cooling towers for central air conditioning systems was investigated under various geometric, physical and environmental conditions. A mathematical model of the shower cooling tower was proposed, and the governing equations considering droplet diameter changes were numerically solved during evaporation. The results showed that compared with the downward-spraying tower, the upward-spraying tower achieved 15.59% higher cooling efficiency, 4.89% higher exergy efficiency and 34.58% higher heat dissipation. Increasing droplet diameter significantly weakened the tower’s cooling capacity, with heat dissipation decreasing by 78.11% as the diameter increased from 1 mm to 2.25 mm. The cooling efficiency, thermal efficiency and exergy efficiency demonstrated consistent declining trends with increasing droplet diameter. Under high-salinity conditions (105 g/kg), compared with standard salinity (35 g/kg), the average reduction of cooling efficiency was 2.96%, and exergy efficiency decreased by 2.73%. The increase in air velocity from 2.5 m/s to 4.0 m/s led to a 13.76% improvement in cooling efficiency and a 22.44% increase in heat dissipation, and exergy efficiency decreased by less than 2%. Through multi-objective optimization analysis, the cooling efficiency increased by 14.69% and exergy destruction decreased by 37.87%, demonstrating significant potential for energy conservation and carbon emission reduction in central air conditioning applications.Keywords
Funding Information
- Natural Science Foundation of Chongqing, China (CSTB2022NSCQ-MSX1302, CSTB2023NSCQ-MSX0619, cstc2021jxjl90002, 51879154)
- Performance Incentive Guidance Special Project for Research Institutions of Chongqing, China (CSTB2022NSCQ-MSX1302, CSTB2023NSCQ-MSX0619, cstc2021jxjl90002, 51879154)
- National Natural Science Foundation of China (CSTB2022NSCQ-MSX1302, CSTB2023NSCQ-MSX0619, cstc2021jxjl90002, 51879154)
This publication has 22 references indexed in Scilit:
- Field test study on water droplet diameter distribution in the rain zone of a natural draft wet cooling towerApplied Thermal Engineering, 2019
- Investigation on the thermal performance of a novel spray tower with upward spraying and downward gas flowApplied Energy, 2018
- Exergy optimization of cooling tower for HGSHP and HVAC applicationsEnergy Conversion and Management, 2017
- Performance prediction of a shower cooling tower using wavelet neural networkApplied Thermal Engineering, 2016
- Study on the dynamic and thermal performances of a reversibly used cooling tower with upward sprayingEnergy, 2016
- Heat and mass transfer processes between a water spray and ambient air – I. Experimental dataApplied Thermal Engineering, 2008
- Further investigation on the performance of a shower cooling towerEnergy Conversion and Management, 2008
- Performance characteristics of a shower cooling towerEnergy Conversion and Management, 2007
- Experimental performance of the shower cooling tower in JapanRenewable Energy, 1997
- Performance of the “shower” cooling tower in different climatesRenewable Energy, 1997