Tunable microlens array fabricated by a silicone oil-induced swelled polydimethylsiloxane (PDMS) membrane bonded to a micro-milled microfluidic chip
Authors:
- Pin-Chuan ChenPCPin-Chuan Chen
- Liang-Ta ChenLCLiang-Ta Chen
- Cing-Sung YehCYCing-Sung Yeh
- 21 September 2020
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (20) , 29815-29828
Abstract
Microlens arrays (MLAs) nowadays are critical micro-optical components and they can be applied in many application fields, such as optical communication systems and flat panel display modules. This article describes a novel approach to the fabrication of tunable, highly reliable, and uniform polydimethylsiloxane (PDMS) MLAs. A polydimethylsiloxane (PDMS) membrane is bonded to a micro-milled poly(methyl methacrylate) (PMMA) microfluidic chip and exposed to silicone oil of a specific viscosity. Molecules in the oil insert themselves into the molecular structure of the PDMS membrane, causing it to swell and subsequently form dome-shaped MLAs. From our experiments, we derived the following conclusions. First, the homogeneous swelling of the PDMS resulted in MLAs with a high numerical aperture (0.5), high uniformity illumination (CV of the illumination intensity is between 2.5%∼5.1%), and high uniformity (CV of sag height of MLAs is less than 0.05). Second, the shorter molecular chains in low-viscosity oils diffused more readily into the PDMS membrane, which increased the effects on swelling, resulting in MLAs with higher sag height and higher numerical aperture. For example, the 5 cst silicone oil resulted in sag height of 191 µm with NA of 0.50, whereas the 100 cst silicone oil resulted in sag height of 86 µm with numerical aperture of 0.33. Finally, the integrated mixer module enabled the simultaneous tuning of the 7 × 7 MLAs simply by adjusting the injection flow rates of the constituent silicone oils.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (MOST 108-2221-E-011-144-MY2)
This publication has 26 references indexed in Scilit:
- Microchannel deformations due to solvent-induced PDMS swellingLab on a Chip, 2010
- Electrowetting on a Polymer Microlens ArrayLangmuir, 2010
- A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperatureLab on a Chip, 2010
- A liquid-filled tunable double-focus microlensOptics Express, 2009
- Tunable microdoublet lens arrayOptics Express, 2004
- Variable-focusing microlens with microfluidic chipJournal of Micromechanics and Microengineering, 2004
- Single-step fabrication of a microlens array in sol–gel material by direct laser writing and its application in optical couplingJournal of Optics A: Pure and Applied Optics, 2003
- Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic DevicesAnalytical Chemistry, 2003
- Design and Fabrication of Microlens Array for Near-Field Vertical Cavity Surface Emitting Laser Parallel Optical HeadOptical Review, 2003
- Shack Hartmann wave-front measurement with a large F-number plastic microlens arrayApplied Optics, 1996