Gastrointestinal Air Motion Artifact Which Can Be Mistaken for Active Gastrointestinal Bleeding in Multidetector Computed Tomography: Phantom and Clinical Study
- 1 January 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 44 (1) , 145-152
Abstract
Objectives We investigated the computed tomographic characteristics of gastrointestinal air motion artifact (GIAMA), which can be misinterpreted as active gastrointestinal bleeding. Methods We simulated GIAMA using 3 types of air-ball phantoms (air-ball in water, air-ball in oil, air-water-ball in oil) and a bovine intestine in oil phantom. We also performed a retrospective clinical review of precontrast abdominal computed tomography images of 76 patients to investigate the frequency, location, shape, and maximum density of hyperdense GIAMA. Results In phantom studies, air motion artifacts appeared as dark and bright streak artifacts at the borders of a moving air-ball and water or oil. In the clinical study, hyperdense GIAMA was visualized in 60 (79.0%) of 76 patients. The small intestine was most commonly affected (46.4%), and the intramural type had the highest frequency (58.0%). Conclusion Knowing the radiologic features of GIAMA can assists radiologists in identifying active gastrointestinal bleeding sites accurately.Keywords
This publication has 11 references indexed in Scilit:
- Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom studyAbdominal Radiology, 2016
- Multidetector CT Angiography for Acute Gastrointestinal Bleeding: Technique and FindingsRadioGraphics, 2013
- Accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding: systematic review and meta-analysisEuropean Radiology, 2012
- Acute Lower Intestinal Bleeding: Feasibility and Diagnostic Performance of CT AngiographyRadiology, 2012
- Multidetector CT Angiography in Acute Gastrointestinal Bleeding: Why, When, and HowRadioGraphics, 2011
- Artifacts in CT: Recognition and AvoidanceRadioGraphics, 2004
- Motion Artifacts in Subsecond Conventional CT and Electron-Beam CT: Pictorial Demonstration of Temporal ResolutionRadioGraphics, 2000
- CLINICAL SCORING SYSTEMS FOR DETERMINING THE PROGNOSIS OF GASTROINTESTINAL BLEEDINGGastroenterology Clinics of North America, 2000
- Causes and Outcome of Upper and Lower Gastrointestinal BleedingSouthern Medical Journal, 1999
- Management of the Adult Patient With Acute Lower Gastrointestinal BleedingAmerican Journal of Gastroenterology, 1998