Addressing the Need for a Specialized Disconnection Device in Catheter Connection Management: A Case Study of User-Centered Medical Device Innovation
Open Access
- 24 January 2025
- journal article
- research article
- Published by MDPI AG in Nursing Reports
- Vol. 15 (2) , 36
Abstract
Background/Objectives: Improvements in catheter connection design intended to increase safety have resulted in connections that are difficult to release manually. No medical device exists to safely disconnect catheter connections. Nurses and other users have developed workarounds including use of hemostats, tourniquets, and wrenches. These workarounds are not always successful for performing this task and can break catheters and catheter connections. This study aimed to evaluate a disconnection device to safely disconnect catheter connections. Methods: This is a mixed-methods study using a user-centered design approach with triangulation of quantitative and qualitative data mapped to Valdez’s sociotechnical framework. Nurses (N = 139) from units across two academic medical centers encompassing diverse patient populations engaged in usability testing and surveys. Data about users’ past catheter disconnection experiences and usability of the specialized disconnection device were collected and analyzed. Triangulation of quantitative data and qualitative themes was mapped using Valdez’s socio-technical framework to complement and strengthen the final design generated for nurses’ user requirements. Results: Ninety-five percent of nurses reported previous difficulty with disconnecting luer connections; 93% of those reporting difficulty improvised with readily available medical devices or products to better grip the connected parts. Over 85% of nurses reported positive experiences using the specialized disconnection device; others suggested design improvements for better performance. Conclusions: The nurses who tested the developed disconnection device reported high acceptability, accessibility, ease of use, and improved task performance. Moreover, as workarounds develop at points of practice where no systematic solution exists, aiming product development activities at these points help close gaps in achieving and maintaining patient safety. This study was not registered.Keywords
Funding Information
- National Center for Advancing Translational Sciences (NCATS), National Institutes of Health (UM1TR004406)
This publication has 25 references indexed in Scilit:
- Central Line Care and Management: Adopting Evidence-Based Nursing InterventionsJournal of PeriAnesthesia Nursing, 2021
- When empowered nurses are under stress: Understanding the impact on attitudes and behavioursStress and Health, 2019
- Evidence‐Based Strategies and Recommendations for Preservation of Central Venous Access in ChildrenJournal of Parenteral and Enteral Nutrition, 2019
- Scrubbing technique for needleless connectors to minimize contamination riskJournal of Hospital Infection, 2018
- Human Factors in Medical Device DesignCritical Care Nursing Clinics of North America, 2018
- An information model to support user-centered design of medical devicesJournal of Biomedical Informatics, 2016
- Central Line Associated Blood Stream Infections in Pediatric Hematology/Oncology Patients With Different Types of Central LinesPediatric Blood & Cancer, 2016
- Guidelines for the Prevention of Intravascular Catheter-related InfectionsClinical Infectious Diseases, 2011
- Strategies to Prevent Central Line–Associated Bloodstream Infections in Acute Care HospitalsInfection Control & Hospital Epidemiology, 2008
- The impact of home parenteral nutrition on daily life—A reviewClinical Nutrition, 2007