Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure
Open Access
- 1 July 2004
- journal article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 88 (7) , 942-946
Abstract
Background: Temporalis fascia has been recommended for hydroxyapatite sphere exposure. The aim of this study was to identify potential risk factors for exposure of porous polyethylene (Medpor) sphere implants and evaluate the use of autogenous temporalis fascia as a patch graft for exposure. Methods: A retrospective review of consecutive cases of porous polyethylene sphere orbital implant exposure. Results: Five cases presented between May 2000 and October 2001 (three males, two females; mean age 44.5 years). Three had enucleation (two with primary implants) and two had evisceration (one with primary implant). Exposure occurred in one primary, two secondary, and two replacement implants. Orbital implant diameter was 20 mm in four cases and 16 mm in one case (contracted socket). The mean time from implantation to exposure was 23 months (range 0.7–42.6). Three patients had secondary motility peg placement before exposure. The average time from last procedure (sphere implant or peg insertion) to exposure was 3 months (range 0.7–12.6). Four patients required surgical intervention, of which three needed more than one procedure. Autogenous temporalis fascia grafting successfully closed the defect without re-exposure in three of these four patients. The grafts were left bare in three patients, with a mean time to conjunctivalise of 2.4 months (range 1.6–3.2). Conclusions: Exposed porous polyethylene sphere implants were treated successfully with autogenous temporalis fascia graft in three of four patients. This technique is useful, the graft easy to harvest, and did not lead to prolonged socket inflammation, infection, or extrusion.Keywords
This publication has 26 references indexed in Scilit:
- Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (medpor)11The authors have no proprietary interest in any of the materials used in this study.Ophthalmology, 2000
- Exposure of primary orbital implants in postenucleation retinoblastoma patients11The authors have no financial or proprietary interest in any of the materials used in this study.Ophthalmology, 2000
- Intraorbital Implants After Enucleation and Their ComplicationsArchives of Ophthalmology (1950), 1998
- Complications of Hydroxyapatite Orbital ImplantsOphthalmology, 1997
- Periocular Autografts in Socket ReconstructionOphthalmology, 1996
- Complications of Porous Spherical Orbital ImplantsOphthalmology, 1995
- Long-term Follow-up of the Allen ImplantOphthalmology, 1995
- Problems with the hydroxyapatite orbital implant: experience with 250 consecutive cases.British Journal of Ophthalmology, 1994
- Tissue Breakdown and Exposure Associated with Orbital Hydroxyapatite ImplantsAmerican Journal of Ophthalmology, 1992
- A Long-Term Follow-Up Study of Scleral Grafting for Exposed or Extruded Orbital ImplantsAmerican Journal of Ophthalmology, 1982