Abstract
This study was designed to evaluate the efficacy and safety of Amplatzer Vascular Plug type 4 (AVP-4) for embolization of the inferior mesenteric artery (IMA) before endovascular aneurysm repair (EVAR) of the abdominal aorta to prevent endoleaks. A single-center retrospective review of 31 patients who underwent IMA embolizations before EVAR using the AVP-4 was performed. We analyzed the insertion and detachment procedure, the technical success, and the final position of the plug. Technical success was defined as complete occlusion of the IMA. To compare the incidence of IMA-related type II endoleaks in patients with and without preoperative IMA embolization, we additionally reviewed the course of 43 patients with a preoperatively patent IMA who underwent no IMA embolization. Plugs with a diameter of 5, 6, and 8 mm were used in 5 (16.1 %), 21 (67.7 %), and 5 (16.1 %) patients, respectively (50–100 % oversizing). In 29 of 31 patients (93.5 %), we observed complete occlusion of the IMA within 10 min (mean 5.1 min). Precise placement of the plug in the proximal segment of the IMA without occlusion of the first IMA branches was achievable in all patients. The distance between the AVP-4 and the first branches was on average 12 (range 2–57) mm. Preoperative IMA embolization with AVP-4 significantly reduced the incidence of complex IMA-lumbar type II endoleaks after EVAR (0/31 vs. 11/43; p = 0.002). The AVP-4 is a safe, feasible, and technically effective embolization device for IMA embolization before EVAR.Keywords
This publication has 21 references indexed in Scilit:
- Preoperative Inferior Mesenteric Artery Embolization before Endovascular Aneurysm Repair: Decreased Incidence of Type II Endoleak and Aneurysm Sac Enlargement with 24-month Follow-upJournal of Vascular and Interventional Radiology, 2013
- The relationship of preoperative thrombus load and location to the development of type II endoleak and sac regressionJournal of Vascular Surgery, 2011
- Preoperative variables predict persistent type 2 endoleak after endovascular aneurysm repairJournal of Vascular Surgery, 2010
- Inferior Mesenteric Artery Embolization before Endovascular Repair of an Abdominal Aortic Aneurysm: Effect on Type II Endoleak and Aneurysm ShrinkageJournal of Vascular and Interventional Radiology, 2010
- Strategies to Reduce the Rate of Type II Endoleaks:Routine Intraoperative Embolization of the Inferior Mesenteric Artery and Thrombin Injection Into the Aneurysm SacJournal of Endovascular Therapy, 2007
- Persistent type 2 endoleak after endovascular repair of abdominal aortic aneurysm is associated with adverse late outcomesJournal of Vascular Surgery, 2007
- Aneurysm Sac Thrombus Load Predicts Type II Endoleaks after Endovascular Aneurysm RepairAnnals of Vascular Surgery, 2005
- Inferior Mesenteric Artery Embolization before Endovascular Aneurysm Repair: Technique and Initial ResultsJournal of Vascular and Interventional Radiology, 2004
- Endovascular Stent-Graft in Abdominal Aortic Aneurysms: The Relationship between Patent Vessels that Arise from the Aneurysmal Sac and Early EndoleakRadiology, 2001
- Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleak in patients undergoing endovascular repair of abdominal aortic aneurysmsJournal of Vascular Surgery, 2000