Novel Mg-0.5Ca-xMn Biodegradable Alloys Intended for Orthopedic Application: An In Vitro and In Vivo Study
Authors:
- Corneliu MunteanuCorneliu Munteanu
- Daniela Maria VladDVDaniela Maria Vlad
- Eusebiu-Viorel SindilarESEusebiu-Viorel Sindilar
- Bogdan IstrateBogdan Istrate
- Maria ButnaruMBMaria Butnaru
- Sorin Aurelian PascaSPSorin Aurelian Pasca
- Roxana Oana NastasaRNRoxana Oana Nastasa
- Iuliana MihaiIMIuliana Mihai
- Stefan-Lucian BurleaSBStefan-Lucian Burlea
Open Access
- 27 November 2021
- Vol. 14 (23) , 7262
Abstract
Mg-based biodegradable materials, used for medical applications, have been extensively studied in the past decades. The in vitro cytocompatibility study showed that the proliferation and viability (as assessed by quantitative MTT-assay—3-(4,5-dimethyltiazol-2-yl)-2,5-diphenyl tetrazolium bromide) were not negatively affected with time by the addition of Mn as an alloying element. In this sense, it should be put forward that the studied alloys don’t have a cytotoxic effect according to the standard ISO 10993-5, i.e., the level of the cells’ viability (cultured with the studied experimental alloys) attained both after 1 day and 5 days was over 82% (i.e., 82, 43–89, 65%). Furthermore, the fibroblastic cells showed variable morphology (evidenced by fluorescence microscopy) related to the alloy sample’s proximity (i.e., related to the variation on the Ca, Mg, and Mn ionic concentration as a result of alloy degradation). It should be mentioned that the cells presented a polygonal morphology with large cytoplasmic processes in the vicinity of the alloy’s samples, and a bipolar morphology in the remote region of the wells. Moreover, the in vitro results seem to indicate that only 0.5% Mn is sufficient to improve the chemical stability, and thus the cytocompatibility; from this point of view, it could provide some flexibility in choosing the right alloy for a specific medical application, depending on the specific parameters of each alloy, such as its mechanical properties and corrosion resistance. In order to assess the in vivo compatibility of each concentration of alloy, the pieces were implanted in four rats, in two distinct body regions, i.e., the lumbar and thigh. The body’s reaction was followed over time, 60 days, both by general clinical examinations considering macroscopic changes, and by laboratory examinations, which revealed macroscopic and microscopic changes using X-rays, CT(Computed Tomography), histology exams and SEM (Scanning Electron Microscopy). In both anatomical regions, for each of the tested alloys, deformations were observed, i.e., a local reaction of different intensities, starting the day after surgery. The release of hydrogen gas that forms during Mg alloy degradation occurred immediately after implantation in all five of the groups examined, which did not affect the normal functionality of the tissues surrounding the implants. Imaging examinations (radiological and CT) revealed the presence of the alloy and the volume of hydrogen gas in the lumbar and femoral region in varying amounts. The biodegradable alloys in the Mg-Ca-Mn system have great potential to be used in orthopedic applications.Keywords
Funding Information
- This work was supported by a publications grant of the TUIASI, project number GI/P8/2021 (GI/P8/2021)
This publication has 29 references indexed in Scilit:
- Preparation and characterization of a new biomedical Mg–Zn–Ca alloyMaterials & Design (1980-2015), 2012
- Microstructure analysis and corrosion behavior of biodegradable Mg–Ca implant alloysMaterials & Design (1980-2015), 2012
- MAO-DCPD composite coating on Mg alloy for degradable implant applicationsMaterials Letters, 2011
- Biphasic calcium sulfate dihydrate/iron-modified alpha-tricalcium phosphate bone cement for spinal applications:in vitrostudyBiomedical Materials, 2010
- Degradable biomaterials based on magnesium corrosionCurrent Opinion in Solid State and Materials Science, 2008
- Control of biodegradation of biocompatable magnesium alloysCorrosion Science, 2007
- Influence of Mn content on mechanical properties and fatigue behavior of extruded Mg alloysMaterials Science and Engineering: A, 2006
- The Zinc- and Calcium-binding S100B Interacts and Co-localizes with IQGAP1 during Dynamic Rearrangement of Cell MembranesJournal of Biological Chemistry, 2002
- Effect of high osmolarity acclimation on tolerance to hyperosmotic shocks in L929 cultured cellsTissue and Cell, 1995
- Rapid colorimetric assay for cellular growth and survival: Application to proliferation and cytotoxicity assaysJournal of Immunological Methods, 1983