Abstract
Current discussions of the applicability of classical standard models to calculate limit values for emission measurements in fully and semi anechoic chambers for frequencies above 1 GHz lead to a high interest to efficiently model unintentional random radiators at high frequencies. Since the radiation pattern of such sources is inherently very inhomogeneous, a high impact on the measurement procedures used in semi and fully anechoic chambers is expected. To quantify this impact, a Monte Carlo model of a physical random radiator is used. The generated radiation patterns are analyzed to represent typical test scenarios. The simulated test results are then evaluated statistically to add quantitative data to the discussion, whether standard test procedures are sufficient at high frequencies or not.