Patch‐based generation of a pseudo CT from conventional MRI sequences for MRI‐only radiotherapy of the brain
- 17 March 2015
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1596-1605
Abstract
Purpose:: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so‐called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel‐intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel‐based or atlas‐based models have typically been used. The voxel‐based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas‐based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of a patch‐based method for creating a pCT based on conventionalT1‐weighted MRI scans without using deformable registrations. We compare this method against two state‐of‐the‐art methods within the voxel‐based and atlas‐based categories.Methods:: The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel‐wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan.Results:: The pCTs produced with the patch‐based method had the best voxel‐wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas‐based method. In terms of the dosimetric accuracy, the patch‐based method had average deviations of less than 0.5% in measures related to target coverage.Conclusions:: We showed that a patch‐based method could generate an accurate pCT based on conventionalT1‐weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel‐based and atlas‐based methods and showed a promising potential for RT of the brain based only on MRI.Keywords
Funding Information
- Varian Medical Systems (Varian Medical Systems, Inc.)
- Varian Medical Systems
- Varian Medical Systems
This publication has 36 references indexed in Scilit:
- MRI-Based Attenuation Correction for Hybrid PET/MRI Systems: A 4-Class Tissue Segmentation Technique Using a Combined Ultrashort-Echo-Time/Dixon MRI SequenceJournal of Nuclear Medicine, 2012
- Results of a Multi-Institutional Benchmark Test for Cranial CT/MR Image RegistrationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- 3. Special Considerations Regarding Absorbed-Dose and Dose–Volume Prescribing and Reporting in IMRTJournal of the ICRU, 2010
- Systematisation of spatial uncertainties for comparison between a MR and a CT-based radiotherapy workflow for prostate treatmentsRadiation Oncology, 2009
- MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas RegistrationJournal of Nuclear Medicine, 2008
- Selective 3D ultrashort TE imaging: comparison of “dual-echo” acquisition and magnetization preparation for improving short-T 2 contrastMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- New variants of a method of MRI scale standardizationIEEE Transactions on Medical Imaging, 2000
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945