Implementation of Dual-Source RF Excitation in 3 T MR-Scanners Allows for Nearly Identical ADC Values Compared to 1.5 T MR Scanners in the Abdomen
Authors:
Open Access
- 29 February 2012
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (2) , e32613
Abstract
To retrospectively and prospectively compare abdominal apparent diffusion coefficient (ADC) values obtained within in a 1.5 T system and 3 T systems with and without dual-source parallel RF excitation techniques. After IRB approval, diffusion-weighted (DW) images of the abdomen were obtained on three different MR systems (1.5 T, a first generation 3 T, and a second generation 3 T which incorporates dual-source parallel RF excitation) on 150 patients retrospectively and 19 volunteers (57 examinations total) prospectively. Seven regions of interest (ROI) were throughout the abdomen were selected to measure the ADC. Statistical analysis included independent two-sided t-tests, Mann-Whitney U tests and correlation analysis. In the DW images of the abdomen, mean ADC values were nearly identical with nonsignificant differences when comparing the 1.5 T and second generation 3 T systems in all seven anatomical regions in the patient population and six of the seven in the volunteer population (p>0.05 in all distributions). The strength of correlation measured in the volunteer population between the two scanners in the kidneys ranged from r = 0.64–0.88 and in the remaining regions (besides the spleen), r>0.85. In the patient population the first generation 3 T scanner had different mean ADC values with significant differences (p<0.05) compared to the other two scanners in each of the seven distributions. In the volunteer population, the kidneys shared similar ADC mean values in comparison to the other two scanners with nonsignificant differences. A second generation 3 T scanner with dual-source parallel RF excitation provides nearly identical ADC values compared with the 1.5 T imaging system in abdominal imaging.Keywords
This publication has 28 references indexed in Scilit:
- Locally Advanced Rectal Carcinoma Treated with Preoperative Chemotherapy and Radiation Therapy: Preliminary Analysis of Diffusion-weighted MR Imaging for Early Detection of Tumor Histopathologic DownstagingRadiology, 2010
- Diffusion-weighted MR Imaging of the LiverRadiology, 2010
- Characterization of Genitourinary Lesions with Diffusion-weighted ImagingRadioGraphics, 2009
- Reproducibility and changes in the apparent diffusion coefficients of solid tumours treated with combretastatin A4 phosphate and bevacizumab in a two-centre phase I clinical trialEuropean Radiology, 2009
- T1 Hyperintense Renal Lesions: Characterization with Diffusion-weighted MR Imaging versus Contrast-enhanced MR ImagingRadiology, 2009
- Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR ImagingRadiology, 2009
- Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and RecommendationsNeoplasia, 2009
- Diffusion-weighted magnetic resonance imaging in the early detection of response to chemoradiation in cervical cancerGynecologic Oncology, 2008
- Apparent Diffusion Coefficient: Potential Imaging Biomarker for Prediction and Early Detection of Response to Chemotherapy in Hepatic MetastasesRadiology, 2008
- Malignant renal neoplasms: correlation between ADC values and cellularity in diffusion weighted magnetic resonance imaging at 3 TLa radiologia medica, 2008