Characterization of a temperature-Controlled FAIMS system
- 1 September 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 18 (9) , 1653-1663
Abstract
High-field asymmetric waveform ion mobility spectrometry (FAIMS) focuses and separates gas-phase analyte ions from chemical background, offering substantial improvements in the detection of targeted species in biological matrices. Ion separations have been typically performed at atmospheric pressure and ambient temperature, although routine small molecule quantitation by LC-MS (and thus LC-FAIMS-MS) is generally performed at liquid flow rates (e.g., in excess of 200 microL/min) in which atmospheric pressure ionization sources (e.g., APCI and ESI) need to be run at elevated temperatures to enhance ion desolvation. Heat from the ionization source and/or the mass spectrometer capillary interface is shown to have a significant impact on the performance of a conventional FAIMS electrode set. This study introduces a new FAIMS system that uses gas heating/cooling to quickly reach temperature equilibrium independent of the external temperature conditions. A series of equations and balance plots, which look at the effect of temperature and other variables, on the normalized field strength (E/N), are introduced and used to explain experimental observations. Examples where the ion behavior deviates from the predicted behavior are presented and explanations based on clusters or changes in ion-neutral interactions are given. Consequences of the use of temperature control, and in particular advantages of using different temperature settings on the inner and outer electrodes, for the purpose of manipulating ion separation are described.Keywords
This publication has 30 references indexed in Scilit:
- Rapid Separation and Quantitative Analysis of Peptides Using a New Nanoelectrospray- Differential Mobility Spectrometer−Mass Spectrometer SystemAnalytical Chemistry, 2006
- High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry AnalyzersAnalytical Chemistry, 2006
- EditorialRapid Communications in Mass Spectrometry, 2005
- Removal of metabolite interference during liquid chromatography/tandem mass spectrometry using high‐field asymmetric waveform ion mobility spectrometryRapid Communications in Mass Spectrometry, 2005
- Structural characterization of methionine and leucine enkephalins by hydrogen/deuterium exchange and electrospray ionization tandem mass spectrometryRapid Communications in Mass Spectrometry, 2004
- High‐sensitivity quantitation of cabergoline and pergolide using a triple‐quadrupole mass spectrometer with enhanced mass‐resolution capabilitiesJournal of Mass Spectrometry, 2003
- A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric fieldInternational Journal of Mass Spectrometry and Ion Processes, 1993
- Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1987
- Electrospray ion source. Another variation on the free-jet themeThe Journal of Physical Chemistry, 1984
- Direct liquid introduction/thermospray interface for liquid chromatography/mass spectrometryAnalytical Chemistry, 1983