Abstract
The study aimed to model the cerebrovascular system, using a linear ARX model based on data simulated by a comprehensive physiological model, and to assess the range of applicability of linear parametric models. Arterial blood pressure (ABP) and middle cerebral arterial blood flow velocity (MCAV) were measured from 11 subjects non-invasively, following step changes in ABP, using the thigh cuff technique. By optimising parameters associated with autoregulation, using a non-linear optimisation technique, the physiological model showed a good performance (r=0.83±0.14) in fitting MCAV. An additional five sets of measured ABP of length 236±154 s were acquired from a subject at rest. These were normalised and rescaled to coefficients of variation (CV=SD/mean) of 2% and 10% for model comparisons. Randomly generated Gaussian noise with standard deviation (SD) from 1% to 5% was added to both ABP and physiologically simulated MCAV (SMCAV), with ‘normal’ and ‘impaired’ cerebral autoregulation, to simulate the real measurement conditions. ABP and SMCAV were fitted by ARX modelling, and cerebral autoregulation was quantified by a 5 s recovery percentage R5% of the step responses of the ARX models. The study suggests that cerebral autoregulation can be assessed by computing the R5% of the step response of an ARX model of appropriate order, even when measurement noise is considerable.Keywords
This publication has 11 references indexed in Scilit:
- A new mathematical model of dynamic cerebral autoregulation based on a flow dependent feedback mechanismPhysiological Measurement, 2001
- Estimating normal and pathological dynamic responses in cerebral blood flow velocity to step changes in end-tidal pCO2Medical & Biological Engineering & Computing, 2000
- Multivariate dynamic analysis of cerebral blood flow regulation in humansIEEE Transactions on Biomedical Engineering, 2000
- Frequency-domain analysis of cerebral autoregulation from spontaneous fluctuations in arterial blood pressureMedical & Biological Engineering & Computing, 1998
- Assessment of Cerebral Autoregulation Using Carotid Artery CompressionStroke, 1996
- Comparison of Static and Dynamic Cerebral Autoregulation MeasurementsStroke, 1995
- Intracranial pressure dynamics in patients with acute brain damage: a critical analysis with the aid of a mathematical modelIEEE Transactions on Biomedical Engineering, 1995
- Assessment of Autoregulation by Means of Periodic Changes in Blood PressureStroke, 1995
- Effect of temperature on finger artery pressure evaluated by volume clamp techniqueClinical Physiology and Functional Imaging, 1993
- Cerebral autoregulation dynamics in humans.Stroke, 1989