Abstract
Background: In calcaneal fractures, the percutaneous screw fixation (PSF) is currently considered to be the better choice, but it is difficult to accurately place the screw into the sustentaculum tali (ST) during the operation. In this study, the ideal entry point, angle, diameter and length of the screw were calculated by simulating the operation process. Methods: We retrospectively collected the calcaneus computed tomography (CT) scans of 180 adults, DICOM-formatted CT-scan images of each patient were imported into Mimics software to establish calcaneus model. Virtual screws were placed on the lateral of the posterior talar articular surface (PTAS), the lateral edge of the anterior process of calcaneus (APC), and the calcaneal tuberosity, respectively, the trajectory and size of the screws were calculated. Results: The mean maximum diameter of the PTAS screw was 42.20 ± 3.71 mm. The vertical distance between the midpoint of the APC optimal screw trajectory and the lowest point of the tarsal sinus was 10.67 ± 1.84 mm, and the distance between the midpoint of the APC optimal screw trajectory and the calcaneocuboid joint was 5 mm ~ 19.81 ± 2.08 mm. The mean maximum lengths of APC screws was 44.69 ± 4.81 mm, and the Angle between the screw and the coronal plane of the calcaneus from proximal to distal was 4.72°±2.15° to 20.52°±3.77°. The optimal point of the maximum diameter of the calcaneal tuberosity screw was located at the lateral border of the achilles tendon endpoint. The mean maximum diameters of calcaneal tuberosity screws was 4.46 ± 0.85 mm, the mean maximum lengths of screws was 65.31 ± 4.76 mm. We found gender-dependent differences for the mean maximum diameter and the maximum length of the three screws. Conclusions: The study provides effective positioning for percutaneous screw fixation of calcaneal fractures. For safer and more efficient screw placement, we suggest individualised preoperative 3D reconstruction simulations. Further biomechanical studies are needed to verify the function of the screw.Keywords
Funding Information
- Natural Science Foundation of Shandong Province (No. ZR202102280280, No. ZR202102280280, No. ZR202102280280)
This publication has 22 references indexed in Scilit:
- Screw Placement Relative to the Calcaneal Fracture Constant Fragment: An Anatomic StudyThe Journal of Foot and Ankle Surgery, 2015
- Comparison of the Outcomes of Two Operational Methods Used for the Fixation of Calcaneal FractureCell Biochemistry and Biophysics, 2015
- The sustentaculum tali screw fixation for the treatment of Sanders type II calcaneal fracture: A finite element analysisPakistan Journal of Medical Sciences, 2014
- Maximizing Safety in Screw Placement for Posterior Facet Fixation in Calcaneus FracturesFoot & Ankle International, 2013
- Assessing Accuracy of Sustentaculum Screw Placement During Calcaneal FixationFoot & Ankle International, 2013
- Surgical versus nonsurgical treatment of displaced intra-articular calcaneal fracture: a meta-analysis of current evidence baseInternational Orthopaedics, 2012
- Sustentaculum-tali-Schraubenplatzierung bei der Versorgung von Kalkaneusfrakturen – verschiedene Navigationsverfahren im Vergleich zur konventionellen TechnikZeitschrift für Orthopädie und Unfallchirurgie, 2010
- Intraoperative 3D Imaging in Calcaneal Fracture Care—Clinical Implications and Decision MakingJournal of Trauma: Injury, Infection & Critical Care, 2009
- The Sustentaculum Tali: Anatomic, Radiographic, and Surgical ConsiderationsFoot & Ankle International, 2000
- Placement of Screws in the Sustentaculum TaliClinical Orthopaedics and Related Research, 1998