A Prospective Pediatric Clinical Trial of Digital Music Players: Do They Interfere with Pacemakers?
Authors:
- June HuhJHJune Huh
- Laura DE SouzaLSLaura DE Souza
- Laura FenwickLFLaura Fenwick
- Robert M. HamiltonRHRobert M. Hamilton
- Elizabeth A. StephensonESElizabeth A. Stephenson
- 29 December 2008
- journal article
- clinical trial
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 20 (1) , 44-49
Abstract
Background: There has been recent concern in the media about iPod™ interference with pacemakers. We systematically tested two types of digital music players (DMP) on pacemaker or ICD function in children. Methods/Results: Patients were monitored by a 6‐lead ECG and programmer telemetry. The pacemaker was tested in bipolar and unipolar sensing at normal and maximal sensitivities. The order of DMP tested was randomized. Each DMP was placed on top of the pacemaker pocket, put into “play” mode three times (5 seconds each), with and without programmer wand placed one cm adjacent to DMP. Pacemaker interference was defined as: pacing inhibition, inappropriate pacing, oversensing, or detection of high‐rate episodes associated with the use of DMP. Of the 67 patients (mean age 12 ± 5 years), 62 had pacemakers and five had ICDs; 39 endocardial and 28 epicardial systems. Patients were tested with Sansa™ (67), iPod™ 30 GB (51), and other DMPs (43). There was no evidence of interference with pacemaker function by any DMP under any of the study conditions (each performed in triplicate). Reproducible programmer telemetry interference was shown in 11 cases (Medtronic 6/47, St. Jude Medical 5/18, Guidant 0/2) related to use of iPod™ (6), Sansa™ (1), or others (4). None of these were associated with any evidence of pacemaker malfunction. Conclusion: Interference with pacemaker function could not be shown with iPod™ or MP3 players. No additional precaution beyond standard is necessary for patients with pacemakers when they are using these players.Keywords
This publication has 16 references indexed in Scilit:
- Electromagnetic interference with pacemakers caused by portable media playersHeart Rhythm, 2008
- Digital music players cause interference with interrogation telemetry for pacemakers and implantable cardioverter-defibrillators without affecting device functionHeart Rhythm, 2008
- Low frequency magnetic emissions and resulting induced voltages in a pacemaker by iPod portable music playersBioMedical Engineering OnLine, 2008
- Evaluation of Electromagnetic Interference of GSM Mobile Phones with Pacemakers Featuring Remote Monitoring FunctionsPacing and Clinical Electrophysiology, 2006
- Reliability of electromagnetic filters of cardiac pacemakers tested by cellular telephone ringingHeart Rhythm, 2005
- Electromagnetic Interference of Implantable Unipolar Cardiac Pacemakers by an Induction OvenPacing and Clinical Electrophysiology, 2005
- Potential for Personal Digital Assistant Interference With Implantable Cardiac DevicesMayo Clinic Proceedings, 2004
- Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators?JACC, 2003
- Interference with Cardiac Pacemakers by Cellular TelephonesNew England Journal of Medicine, 1997
- A Primer on Pacemaker ProgrammersPacing and Clinical Electrophysiology, 1993