Abstract
Ultrasonic 3D imaging technology is helpful to visually display the shape and distribution of defects, but when the amount of ultrasonic data is large, the 3D imaging reconstruction of non-defect parts waste computer performance, resulting in slow imaging speed. According to the sparseness of the mapped volume data, a moving cube algorithm based on bounding box is proposed for 3D reconstruction. The above algorithm was verified by experiments. The experimental results show that the improved moving cube algorithm can improve the time of reducing the three-dimensional imaging of ultrasound and improve the drawing speed.Keywords
This publication has 7 references indexed in Scilit:
- Global Patch Matching (GPM) for freehand 3D ultrasound reconstructionBioMedical Engineering OnLine, 2017
- A Review on Real-Time 3D Ultrasound Imaging TechnologyBioMed Research International, 2017
- A novel Bayesian-based nonlocal reconstruction method for freehand 3D ultrasound imagingNeurocomputing, 2015
- Reconstruction of freehand 3D ultrasound based on kernel regressionBioMedical Engineering OnLine, 2014
- A Total Variation Based Reconstruction Algorithm for 3D Ultrasound2013
- Volume reconstruction of freehand three-dimensional ultrasound using median filtersUltrasonics, 2008
- Freehand Ultrasound Reconstruction Based on ROI Prior Modeling and Normalized Convolution2003