Abstract
Ultrafine particles (UFP) (Finf) and its variation as a function of several factors becomes of enormous importance in epidemiological studies. The objective of this study is to investigate the transport of UFP into a residential building and to determine the functional dependence of infiltration on particle size and air change rate. A secondary objective was to estimate the values of the penetration coefficient P and composite deposition rate kcomp that enter into the definition of Finf. Using continuous measurements of indoor and outdoor concentrations of size-resolved particles ranging from 5 to 100 nm in a manufactured test house, particle penetration through the building, composite deposition, and the resulting value of Finf were calculated for two cases: closed windows and one window open 7.5 cm. Finf ranged from close to 0 (particles 80 nm) with windows closed and from 0 to 0.6 with one window open. The penetration coefficient (closed windows) increased from about 0.2 for 10-nm particles to an asymptote near 0.6 for particles from 30−100 nm. Open window penetration coefficients were higher, ranging from 0.6 to 0.8. Closed-window composite deposition rates, which included losses to the furnace filter and to the ductwork as well as to interior surfaces, monotonically decreased from levels of about 1.5 h−1 for 10-nm particles to 0.3 h−1 for 100-nm particles. For the open-window case, composite deposition rates were higher for particles −1. Mean standard errors associated with estimates of P, kcomp, and Finf for two series of measurements ranged from 1.0% to 4.4%.

This publication has 32 references indexed in Scilit: