Effective Force Testing: A Method of Seismic Simulation for Structural Testing
Authors:
- 1 September 1999
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 125 (9) , 1028-1037
Abstract
This paper presents a test method for real-time earthquake simulation studies of large scale test structures. The method, effective force testing (EFT), is based on a force control algorithm. For systems that can be modeled as a series of lumped masses (e.g., frame structures where masses are assumed lumped at the floor levels), the EFT forces are known a priori for any acceleration record. As opposed to the pseudodynamic test method (a displacement-based control procedure), there is no computational time required for the EFT method in determining the required force signal; it is known prior to the test once the structural mass and ground acceleration record to be simulated are determined. Research has been conducted on a single-degree-of-freedom system at the University of Minnesota to investigate the potential of the EFT method. A direct application of the method was found ineffective because the actuator was unable to apply force at the natural frequency of the structure owing to actuator/control/structure interaction. However, numerical simulations and experimental implementation indicated that an additional velocity feedback loop incorporated into the control system can overcome this problem while maintaining the ability to do real-time testing.Keywords
This publication has 4 references indexed in Scilit:
- Role of Control-Structure Interaction in Protective System DesignJournal of Engineering Mechanics, 1995
- Development of real‐time pseudo dynamic testingEarthquake Engineering & Structural Dynamics, 1992
- Pseudodynamic Test Method—Current Status and Future DirectionsJournal of Structural Engineering, 1989
- Pseudodynamic Method for Seismic TestingJournal of Structural Engineering, 1985