Comparison of 3 microkeratomes usedfor keratomileusis in situ in a swine model
Authors:
- Heinrich BleckmannHBHeinrich Bleckmann
- 1 January 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 25 (1) , 24-31
Abstract
To determine whether the choice of instrumentation affects the quality and precision of corneal cuts during keratomileusis in situ. Schlosspark-Klinik, Ophthalmology Department, Berlin, Germany. The study was performed on 54 swine eyes and 3 human corneas using microkeratomes manufactured by Steinway, SCMD, and Eye Technology. The study results are based on micrometric and pachymetric measurements of actual slice thickness. Slice thickness and slice quality were evaluated using scanning electron microscopy. Three slices of defined thickness were made with each keratome. There was no significant difference in the degree of deviation of slice thickness from the intended value with any keratome. The micrometric measurement of the first lamella documented significantly less variation in the actual measurements achieved with the Eye Technology device (P < .01). All keratomes tested demonstrated a high degree of congruence between the intended values and those achieved in mean thickness and circularity of the cut. The Eye Technology device demonstrated the best profile and the cleanest margins, followed by the SCMD keratome, which caused minimal distortion of the stroma. The Steinway keratome has a high amplitude and produced 25 microns tears in the margins perpendicular to the plane of the cut. There was no overall difference in cutting precision between the 3 tested keratomes. High-oscillation frequency of the blade resulted in a smooth cut.Keywords
This publication has 13 references indexed in Scilit:
- Intraocular pressure during lamellar cuts with two different microkeratomesDer Ophthalmologe, 1997
- Comparison of the UniversalKeratome and the Automated Corneal ShaperJournal of Cataract & Refractive Surgery, 1996
- Initial results of automated lamellar keratoplasty for correction of myopia: One year follow-upJournal of Cataract & Refractive Surgery, 1996
- Ocular Hypertension and Central Corneal ThicknessOphthalmology, 1995
- Acoustic velocity and attenuation of eye tissues at 20 MHzUltrasound in Medicine & Biology, 1994
- Myopic keratomileusis in situ: A preliminary reportJournal of Cataract & Refractive Surgery, 1991
- In Situ Myopic Keratomileusis Results in 30 Eyes at 15 MonthsJournal of Refractive Surgery, 1991
- Human Cadaver Corneal Thinning for Experimental Refractive SurgeryJournal of Refractive Surgery, 1989
- Morphology of the Pig Cornea in Normal Conditions and after Incubation in a Perfusion ApparatusActa Veterinaria Scandinavica, 1987
- Hypermetropic and Myopic Keratokyphosis???A New Method of Refractive Keratoplasty. I. Effect of a Synthetic Lens on Intraocular PressureCornea, 1982