Abstract
Version of the femoral stem is an important factor influencing the risk of dislocation after total hip replacement (THR) as well as the position of the acetabular component. However, there is no radiological method of measuring stem anteversion described in the literature. We propose a radiological method to measure stem version and have assessed its reliability and validity. In 36 patients who underwent THR, a hip radiograph and CT scan were taken to measure stem anteversion. The radiograph was a modified Budin view. This is taken as a posteroanterior radiograph in the sitting position with 90° hip flexion and 90° knee flexion and 30° hip abduction. The angle between the stem-neck axis and the posterior intercondylar line was measured by three independent examiners. The intra- and interobserver reliabilities of each measurement were examined. The radiological measurements were compared with the CT measurements to evaluate their validity. The mean radiological measurement was 13.36° (sd 6.46) and the mean CT measurement was 12.35° (sd 6.39) (p = 0.096). The intra- and interobserver reliabilities were excellent for both measurements. The radiological measurements correlated well with the CT measurements (p = 0.001, r = 0.877). The modified Budin method appears reliable and valid for the measurement of femoral stem anteversion. Cite this article: Bone Joint J 2013;95-B:877–80.Keywords
This publication has 21 references indexed in Scilit:
- A Comparison of Surgeon Estimation and Computed Tomographic Measurement of Femoral Component Anteversion in Cementless Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2009
- Combined Anteversion Technique for Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2009
- Imaging and Navigation Measurement of Acetabular Component Position in THAClinical Orthopaedics and Related Research, 2009
- The effect of anteversion on femoral component stability assessed by radiostereometric analysisThe Journal of Arthroplasty, 2002
- Measuring anteversion in the femoral neck from routine radiographsActa Radiologica, 1998
- Lack of correlation between femoral neck anteversion and acetabular orientation Radiography and computed tomography in cadavers and in vivoActa Orthopaedica, 1989
- Dislocations after total hip arthroplasty.Journal of Bone and Joint Surgery, 1982
- Anteversion of the Acetabulum in Patients with Idiopathic Increased Anteversion of the Femoral NeckActa Orthopaedica, 1982
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- Prosthetic Hip AngulationRadiology, 1973