Portable multi-focal visual evoked potential diagnostics for multiple sclerosis/optic neuritis patients
Open Access
- 3 July 2024
- journal article
- research article
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 149 (1) , 23-45
Abstract
Purpose: Multiple sclerosis (MS) is a neuro-inflammatory disease affecting the central nervous system (CNS), where the immune system targets and damages the protective myelin sheath surrounding nerve fibers, inhibiting axonal signal transmission. Demyelinating optic neuritis (ON), a common MS symptom, involves optic nerve damage. We’ve developed NeuroVEP, a portable, wireless diagnostic system that delivers visual stimuli through a smartphone in a headset and measures evoked potentials at the visual cortex from the scalp using custom electroencephalography electrodes. Methods: Subject vision is evaluated using a short 2.5-min full-field visual evoked potentials (ffVEP) test, followed by a 12.5-min multifocal VEP (mfVEP) test. The ffVEP evaluates the integrity of the visual pathway by analyzing the P100 component from each eye, while the mfVEP evaluates 36 individual regions of the visual field for abnormalities. Extensive signal processing, feature extraction methods, and machine learning algorithms were explored for analyzing the mfVEPs. Key metrics from patients’ ffVEP results were statistically evaluated against data collected from a group of subjects with normal vision. Custom visual stimuli with simulated defects were used to validate the mfVEP results which yielded 91% accuracy of classification. Results: 20 subjects, 10 controls and 10 with MS and/or ON were tested with the NeuroVEP device and a standard-of-care (SOC) VEP testing device which delivers only ffVEP stimuli. In 91% of the cases, the ffVEP results agreed between NeuroVEP and SOC device. Where available, the NeuroVEP mfVEP results were in good agreement with Humphrey Automated Perimetry visual field analysis. The lesion locations deduced from the mfVEP data were consistent with Magnetic Resonance Imaging and Optical Coherence Tomography findings. Conclusion: This pilot study indicates that NeuroVEP has the potential to be a reliable, portable, and objective diagnostic device for electrophysiology and visual field analysis for neuro-visual disorders.Keywords
All Related Versions
Funding Information
- National Institute of Health (UL1TR002544)
- Northeastern University USA
This publication has 36 references indexed in Scilit:
- A signal-to-noise analysis of multifocal VEP responses: an objective definition for poor recordsDocumenta Ophthalmologica, 2002
- Multifocal objective perimetry in the detection of glaucomatous field lossAmerican Journal of Ophthalmology, 2002
- Imaging visual function with the multifocal m-sequence techniqueVision Research, 2001
- Clinical application of the multifocal VEPsCurrent Eye Research, 2001
- Objective perimetry in glaucoma11Proprietary interest: patent application submitted.Ophthalmology, 2000
- Tracking the recovery of local optic nerve function after optic neuritis: a multifocal VEP study.2000
- An interocular comparison of the multifocal VEP: a possible technique for detecting local damage to the optic nerve.2000
- The topography of visual evoked response properties across the visual fieldElectroencephalography and Clinical Neurophysiology, 1994
- Craniocerebral topography within the international 10–20 systemElectroencephalography and Clinical Neurophysiology, 1989
- Visual Evoked Response in Diagnosis of Multiple SclerosisBMJ, 1973