Ultrasound measurement of skin-to-septum distance in totally implantable venous access ports: Considerations for Huber needle length
- 18 August 2026
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (6) , 2797-2803
Abstract
Background: Objective criteria for selecting Huber needle length for totally implantable venous access ports (TIVAPs) are limited. This study primarily described skin-to-septum distance using ultrasonography and its correlation with body habitus. Methods: Thirty-three patients with TIVAPs for chemotherapy were included. Skin-to-septum distance was measured by ultrasonography in two positions: supine with arms at the sides and with shoulder flexion. Pearson’s correlation coefficient assessed correlation between body mass index (BMI) and septal depth. Excess needle length beyond the port base was calculated. Results: Mean skin-to-septum distance was 1.7 ± 0.4 mm (arms at sides) and 1.8 ± 0.5 mm (shoulder flexion). A 16-mm Huber needle was used in 97.0%. The median excess needle length was 2.4 mm. BMI showed weak correlation with septal depth ( r = 0.33, p = 0.062). Conclusions: Septal depth was shallow, and BMI alone was not a reliable predictor. Ultrasound may support Huber needle selection.Keywords
Funding Information
- Terumo Foundation for Life Sciences and Arts
This publication has 10 references indexed in Scilit:
- Vessel Health and Preservation: The Right Approach for Vascular Access2024
- Infusion Therapy Standards of Practice, 9th EditionJournal of Infusion Nursing, 2024
- Expert consensus on the clinical application of totally implantable venous access devices in the upper arm (2022 Edition)Journal of Interventional Medicine, 2023
- Totally Implantable Venous Access Port Systems: Implant Depth-based Complications in Breast Cancer Therapy - A Comparative StudyCurrent Pharmaceutical Design, 2021
- Incidence, risk factors, and assessment of induration by ultrasonography after chemotherapy administration through a peripheral intravenous catheterJapan Journal of Nursing Science, 2020
- Shanghai expert consensus on totally implantable access ports 2019Journal of Interventional Medicine, 2019
- Correlation of subcutaneous fat measured on ultrasound with Body Mass IndexJournal of Medical Ultrasound, 2018
- Contact dermatitis due to ultrasound gel: A case report and published work reviewThe Journal of Dermatology, 2015
- Chemotherapy Drug Extravasation in Totally Implantable Venous Access Port Systems: How Effective is Early Surgical Lavage?The Journal of Vascular Access, 2014
- Skin Damage Associated With Intravenous TherapyJournal of Infusion Nursing, 2012