Crest factor optimization of the multisine waveform for bioimpedance spectroscopy
Authors:
- Jaan OjarandJOJaan Ojarand
- Mart MinMMMart Min
- Paul AnnusPAPaul Annus
- 20 May 2014
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 35 (6) , 1019-1033
Abstract
The multisine excitation is widely used in impedance measurements to retain the advantages of the sine wave, while reducing the measurement time. Adding up sine waves increases the amplitude of the excitation signal, but, for the linearity assumption to be valid, the overall amplitude of the signal needs to be kept low. Thus, the crest factor (CF) of the excitation signal must be minimized. A novel empirical method for the minimization of the CF is described in this paper. As in the case of other known methods, the computed CF may be guaranteed to be only a local minimum. However, a systematic variation of initial parameters, which is possible due to the sparing algorithm, ensures a CF value very close or equal to the global minimum. The results of CF minimization and comparison with the results from other sources are provided. The direct CF optimization results (set of optimal phases) are not well suited for practical implementation. The influence of phase accuracy on the CF is discussed, and an algorithm for the recalculation of initial phases to the rougher set is described. It is shown that previously obtained optimization results (minimal CF) can be highly preserved, even in the case of rough phase resolutions. The CF of the multisine also depends on the frequency distribution and amplitudes of its components. The CF of multisines with several frequency distributions are compared.Keywords
This publication has 15 references indexed in Scilit:
- Simplified signal processing for impedance spectroscopy with spectrally sparse sequencesJournal of Physics: Conference Series, 2013
- Optimisation of multisine waveform for bio-impedance spectroscopyJournal of Physics: Conference Series, 2013
- Comparison of spectrally sparse excitation signals for fast bioimpedance spectroscopy: In the context of cytometry2012
- Multisine With Optimal Phase-Plane Uniformity for ADC TestingIEEE Transactions on Instrumentation and Measurement, 2011
- Bioimpedance: A Review for Food ProcessingFood Engineering Reviews, 2010
- Optimization-based design of plant-friendly multisine signals using geometric discrepancy criteriaComputational Optimization and Applications, 2007
- A genetic algorithm-based method for synthesis of low peak amplitude signalsThe Journal of the Acoustical Society of America, 1996
- BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields1995
- Prevention of the Rapid Degradation of Subcutaneously Implanted Ag/AgCl Reference Electrodes Using Polymer CoatingsAnalytical Chemistry, 1994
- Crest-factor minimization using nonlinear Chebyshev approximation methodsIEEE Transactions on Instrumentation and Measurement, 1991