Abstract
Nowadays, the research on the optimal sensor placement (OSP) is very active in the field of leak detection and localization in the water distribution network (WDN). Considering that most of the WDN is an irregular network, this paper proposes a new method for OSP applied to irregular network system conditions. From the initial set of a limited number of sensors placed by node data features, the proposed method makes a completely new change to the limited number of sensor layouts. The solution is based on a graph convolutional network algorithm, which combines node features and graph structure features. In order to verify the effectiveness of the algorithm, the nodes selected by the algorithm in this paper are used to locate the leakage of the pipeline network. By simulating real leakage scenarios, the method is applied to a small WDN (Anytown) and a large WDN (Net3) respectively. The results show that the method proposed in this paper outperforms other comparison algorithms to a certain extent.
Funding Information
  • Science and technology project of The Education Department of Jilin Province, China (JJKH20200983KJ)
  • Natural Science Foundation of the Department of Science and Technology of Jilin Province (20200201046JC)
  • key Science Foundation of the Department of Science and Technology of Jilin Province (20190303082SF)

This publication has 20 references indexed in Scilit: