Reproducibility of the 6‐Minute Step Test in Individuals on Hemodialysis
Open Access
- 21 July 2026
- journal article
- research article
- Published by Wiley in Physiotherapy Research International
- Vol. 31 (3) , e70291
Abstract
Background: Functional impairments are common in individuals with end‐stage renal disease (ESRD) undergoing hemodialysis (HD); however, the clinical assessment of physical function remains challenging due to the limited availability of simple and reliable functional tests validated for this population. Purpose: To evaluate the test‐retest reproducibility of the 6‐minute step test (6MST) in individuals undergoing HD, including the interpretation of measurement error. Methods: This was a cross‐sectional, test retest‐ reliability study conducted in patients receiving maintenance HD. All assessments were performed immediately before the HD session. Participants completed the Kidney Disease Quality of Life 36‐Item Short Form questionnaire (KDQOL SF‐36) and performed two 6MSTs under standardized conditions. Test‐retest reliability was assessed using the intraclass correlation coefficient (ICC). Absolute reliability was evaluated through the standard error of measurement (SEM) and minimal detectable change (MDC). Agreement between tests was examined using Bland–Altman analysis. Results: Fifty patients completed both test sessions. The 6MST demonstrated good test–retest reliability for total steps (ICC = 0.80), with most differences between tests remaining below the MDC95, indicating the absence of a clinically meaningful learning effect. Bland–Altman analysis showed minimal bias and acceptable limits of agreement for both total steps and heart rate measured at the sixth minute of the test. Physiological responses, including oxygen saturation, blood pressure, and perceived exertion, remained stable between sessions. Discussion: The 6 minute step test is a reliable and clinically applicable tool for assessing functional capacity in individuals undergoing hemodialysis. The absence of a relevant learning effect and the stability of physiological responses support its use for functional assessment and follow‐up, even when performed before the hemodialysis session. Further studies should investigate inter‐rater reproducibility and responsiveness to interventions.Keywords
Funding Information
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
This publication has 15 references indexed in Scilit:
- A Tutorial on Sample Size Calculation for Inter-rater and Intra-rater Agreement StudiesIndian Journal of Psychological Medicine, 2026
- Exercise Rehabilitation for People With End-Stage Kidney Disease: Who Will Fill the Gaps?Canadian Journal of Cardiology, 2023
- Cardiac and Noncardiac Determinants of Exercise Capacity in CKDJournal of the American Society of Nephrology, 2021
- Correlation between functional capacity and oxidative stress and inflammation in hemodialysis patientsJournal of Bodywork and Movement Therapies, 2021
- Cardiopulmonary exercise testing in patients with end-stage kidney disease: principles, methodology and clinical applications of the optimal tool for exercise tolerance evaluationNephrology Dialysis Transplantation, 2021
- Six-minute stepper test in hospitalized elderly patients: Convergent validity, test-retest reliability and safetyPLOS ONE, 2020
- Can we use the 6-minute step test instead of the 6-minute walking test? An observational studyPhysiotherapy, 2017
- Validity and Reliability of the 6-Minute Step Test in Healthy IndividualsClinical Journal of Sport Medicine, 2016
- Assessment of Health-Related Quality of Life of Patients after Kidney Transplantation in Comparison with Hemodialysis and Peritoneal DialysisAnnals of Transplantation, 2014
- A step test to assess exercise-related oxygen desaturation in interstitial lung diseaseEuropean Respiratory Journal, 2006