SACTI model in prediction and assessment of large scale natural draft cooling tower environmental impact of nuclear power plant
Authors:
Open Access
- 10 July 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-14
Abstract
Large Scale Natural Draft Cooling Tower has become a hot topic in China because it is an important part of the nuclear power plant, and its environmental impacts include shading, solar energy loss, water deposition and salt deposition. In China, there is no built large-scale natural draft cooling tower of nuclear power plant. Therefore, model prediction becomes an effective way to solve this problem. This paper introduces the basic principles and structure of SACTI (Seasonal and Annual Cooling Tower Impact) model. SACTI is a cooling tower assessment model developed by Argonne National Laboratory, USA. A comparative case study between China's Pengze Nuclear Power Plant and the US Amos Power Plant is also presented. Calculations were carried out for the Pengze and Amos power plants, and the results showed that the maximum value of salt deposition at the Pengze plant was about 166.5 kg/(km2-month) at a distance of 800 m from the cooling tower. The maximum value of salt deposition at the Amos plant was about 92.85 kg/(km2-month) at a distance of 600 m from the cooling tower. Conclusions show that the research work can provide a useful solution in future work, the simulation results of the SACTI model have a potential mean in the absence of monitoring data. This research provides a way to generate simulation data through SACTI program in the design process of nuclear power plant cooling tower, and designers can use these data to determine how the cooling tower will affect the natural environment and manage within an appropriate range to reduce the impact on the environment.Keywords
Funding Information
- Mechanistic Study and Assessment Modeling of the Effect of Cooling Towers on Particle Nuclide Retention at Offshore Nuclear Power Plant Sites (JZ-202211001)
- Analysis of the Particle Size Spectrum of the Effect of the Cooling Tower on Nuclide Particle Dispersion (20221094)
This publication has 14 references indexed in Scilit:
- On the influence of psychrometric ambient conditions on cooling tower drift depositionInternational Journal of Heat and Mass Transfer, 2010
- CFD prediction of cooling tower driftJournal of Wind Engineering and Industrial Aerodynamics, 2006
- A numerical study of interacting buoyant cooling-tower plumesAtmospheric Environment, 2001
- A model for seasonal and annual cooling tower impactsAtmospheric Environment, 1994
- An improved method for predicting seasonal and annual shadowing from cooling tower plumesAtmospheric Environment. Part A. General Topics, 1992
- A second-generation model for cooling tower plume rise and dispersion—I. Single sourcesAtmospheric Environment. Part A. General Topics, 1991
- Cooling tower plume rise analyses by airborne lidarAtmospheric Environment (1967), 1984
- Studies on mathematical models for characterizing plume and drift behavior from cooling towers. Executive summary1981
- Improvement of Mathematical Models for Plume Rise and Drift Deposition from Cooling Towers1980
- The effect of atmospheric conditions on the length of visible cooling tower plumesAtmospheric Environment (1967), 1975