Metal Ion Interpretation in Resurfacing versus Conventional Hip Arthroplasty and in Whole Blood versus Serum. How should we Interpret Metal Ion Data?
- 21 September 2011
- journal article
- research article
- Published by SAGE Publications in HIP International
- Vol. 21 (5) , 587-595
Abstract
Metal ions generated from joint replacements are a cause for concern. There is no consensus on the best surrogate measure of metal ion exposure, and both serum and whole blood measurements are used in clinical practice. This study provides a guideline for interpretation of metal ion analysis in clinical practice. In a prospective trial comparing hip resurfacing (HR) with a conventional metal-on-metal (MoM) total hip arthroplasty (THA) cobalt and chromium levels were determined for whole blood and serum in 343 paired samples at regular intervals up to 24 months postoperatively. Cobalt whole blood and serum levels increased significantly after both procedures. Cobalt concentrations were significantly higher for the HR group compared to the THA group, at 3, 6 and 12 months, for whole blood and serum. At 24 months cobalt levels decreased and differences between HR and THA were no longer significant. In contrast, chromium whole blood levels remained significantly higher for HR until 24 months. Whole blood and serum levels could not be used interchangeably. The mean differences for cobalt and chromium between blood and serum values were +0.13 μg/L and –0.91 μg/L respectively. Regression analysis provided a formula for conversion from serum to blood of 0.34+[0.88*Co serum] for cobalt and 0.14+[0.58*Cr serum] for chromium, with an acceptable prediction error below ±1.0 μg/L. Cobalt and chromium levels were significantly higher for HR versus THA, especially during the run-in phase of one year. Overall, the metal ion levels were well below 5 μg/L. We cannot recommend the use of whole blood over serum measurements or vice versa. The provided conversion formula between whole blood and serum in combination with the presented practical guidelines may be useful for clinical practice.Keywords
This publication has 24 references indexed in Scilit:
- Reduced Articular Surface of One-piece Cups: A Cause of Runaway Wear and Early FailureClinical Orthopaedics and Related Research, 2010
- The John Charnley Award: Metal-on-Metal Hip Resurfacing versus Large-diameter Head Metal-on-Metal Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2010
- Dose-dependent cytotoxicity of clinically relevant cobalt nanoparticles and ions on macrophagesin vitroBiomedical Materials, 2009
- Serum Ion Level After Metal-on-metal THA in Patients With Renal FailureClinical Orthopaedics and Related Research, 2008
- The validity of serum levels as a surrogate measure of systemic exposure to metal ions in hip replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Orthopaedic metals and their potential toxicity in the arthroplasty patientThe Journal of Bone and Joint Surgery. British volume, 2007
- A benign psoas mass following metal-on-metal resurfacing of the hipThe Journal of Bone and Joint Surgery. British volume, 2006
- Distribution of Cobalt Chromium Wear and Corrosion Products and Biologic ReactionsClinical Orthopaedics and Related Research, 1996
- Metal on Metal Total Hip Replacement Workshop Consensus DocumentClinical Orthopaedics and Related Research, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986