Abstract
Objective: Humans produce and exhale CO2, thus the concentration of this gas increases in closed environments. The CO2 concentration of air is often used as a reference to measure the ventilation rate. The typical outdoor CO2 concentration is approximately 400 ppm, although it can be as high as 500 ppm. Concentrations greater than 20000 ppm result in deep breathing, higher than 100000 ppm cause visual disturbances and tremors with possible loss of consciousness and over 250000 ppm may cause death. In buildings with no change on their ventilation rate, high CO2 concentrations have negative effects on decision making and working performance. At 1000 ppm, performance is significantly reduced in six of nine decision-making metrics compared to 600 ppm. In this work, a CO2 flexible monitor is designed to measure ventilation in closed environments. Methodology: Electrolytic and infrared CO2 sensors with a detection range of 350 to up to 10000 ppm were used. The used sensors have good sensitivity and selectivity to CO2. The gas monitor has a simple calibration system, whereby softwareautomatically adjusts the calibration curve parameters after circulating clean air. The design of a gas bench used to verify sensor calibration is also shown. Results: A set of measurements were performed with electrochemical gas sensors and infrared (IR) gas sensors to test the functionality of the equipment. Experimental work has shown sensors have a satisfactory response for this application. The margins of error are +5 % of the reading value. Conclusions: A low cost, flexible gas monitor for indoor environments like schools, offices, laboratories, and industries was designed in this work. Due to the flexible design, a network of gas monitors strategically distributed in the different spaces of the buildings is proposed. Fundings: Universidad Tecnológica Nacional. Comisión Nacional de Energía Atómica. Buenos Aires, ArgentinaKeywords
This publication has 19 references indexed in Scilit:
- Natural ventilation in classrooms for healthy schools in the COVID era in Mediterranean climateBuilding and Environment, 2021
- Recommendations for ventilation of indoor spaces to reduce COVID-19 transmissionJournal of the Formosan Medical Association, 2021
- CO2 concentration monitoring inside educational buildings as a strategic tool to reduce the risk of Sars-CoV-2 airborne transmissionEnvironmental Research, 2021
- Study on ventilation rates and assessment of infection risks of COVID-19 in an outpatient buildingJournal of Building Engineering, 2021
- Mitigating aerosol infection risk in school buildings: the role of natural ventilation, volume, occupancy and CO2 monitoringBuilding and Environment, 2021
- High energy efficiency ventilation to limit COVID-19 contagion in school environmentsEnergy and Buildings, 2021
- COVID-19: How to transform a noninvasive ventilation device in a critical care ventilatorRevista Española de Anestesiología y Reanimación (English Edition), 2020
- Carbon dioxide generation rates for building occupantsIndoor Air, 2017
- Increasing electronic nose recognition ability by sample laser irradiationSensors and Actuators B: Chemical, 2010
- Coarse and fine particles and daily mortality in the Coachella Valley, California: a follow-up studyJournal of Exposure Science & Environmental Epidemiology, 2000