A Threshold-Based Bioluminescence Detector With a CMOS-Integrated Photodiode Array in 65 nm for a Multi-Diagnostic Ingestible Capsule
- 25 August 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (3) , 838-851
Abstract
This article presents a highly miniaturized ingestible electronic capsule for biochemical detection via onboard genetically engineered biosensor bacteria. The core integrated circuit (IC) is a threshold-based bioluminescence detector with a CMOS-integrated photodiode array in a 65-nm technology that utilizes a dual-duty-cycling front end to achieve low power consumption. The implemented IC achieved 59-nW active power consumption, 25-fA/count resolution, and a 59-fA minimum detectable signal (MDS) using a calibrated optical source. The IC was then integrated with other system components into a battery-powered wireless ingestible capsule measuring just 6.5 mm thick $\times $ 12 mm diameter. We demonstrated successful detection of low-intensity bioluminescent signals from bioengineered bacterial sensors when exposed to the intestinal inflammation biomarker tetrathionate in vitro. Together, the IC and mm-scale smart pill systems demonstrate high sensitivity with low-power multiplexed measurement capability suitable for noninvasive disease diagnosis and monitoring in the gastrointestinal (GI) tract.Keywords
Funding Information
- Leona M. and Harry B. Helmsley Charitable Trust (3239)
- Catalyst Foundation
- Translational Research Institute of Space Health (NNX16AO69A)
- Pew Charitable Trusts (00030623)
- Catalyst Foundation
- Department of Mechanical Engineering, Massachusetts Institute of Technology
- Karl van Tassel (1925) Career Development Professorship, MIT
This publication has 50 references indexed in Scilit:
- A Constant Energy-Per-Cycle Ring Oscillator Over a Wide Frequency Range for Wireless Sensor NodesIEEE Journal of Solid-State Circuits, 2016
- Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysisNature, 2016
- A Multi-Modality CMOS Sensor Array for Cell-Based Assay and Drug ScreeningIEEE Transactions on Biomedical Circuits and Systems, 2015
- The StrongARM Latch [A Circuit for All Seasons]IEEE Solid-State Circuits Magazine, 2015
- Biosensors for Whole-Cell Bacterial DetectionClinical Microbiology Reviews, 2014
- Pigment-based whole-cell biosensor system for cadmium detection using genetically engineered Deinococcus radioduransBioprocess and Biosystems Engineering, 2011
- Cell-based biosensor for rapid screening of pathogens and toxinsBiosensors and Bioelectronics, 2010
- Biomolecule‐Functionalized Carbon Nanotubes: Applications in NanobioelectronicsChemphyschem, 2004
- A low-voltage low-power voltage reference based on subthreshold MOSFETsIEEE Journal of Solid-State Circuits, 2003
- Analysis of temporal noise in CMOS photodiode active pixel sensorIEEE Journal of Solid-State Circuits, 2001