Characteristics of Paraspinal Muscle Spindle Response to Mechanically Assisted Spinal Manipulation: A Preliminary Report
Authors:
- 1 July 2017
- journal article
- research article
- Published by National University of Health Sciences in Journal of Manipulative and Physiological Therapeutics
- Vol. 40 (6) , 371-380
Abstract
The purpose of this preliminary study is to determine muscle spindle response characteristics related to the use of 2 solenoid powered clinical mechanically assisted manipulation (MAM) devices. L6 muscle spindle afferents with receptive fields in paraspinal muscles were isolated in 6 cats. Neural recordings were made during L7 MAM thrusts using the Activator V (Activator Methods Int. Ltd., Phoenix, AZ) and/or Pulstar (Sense Technology Inc., Pittsburgh, PA) devices at their 3 lowest force settings. Mechanically assisted manipulation response measures included (a) the time required post-thrust until the first action potential, (b) differences in mean frequency (MF) and mean instantaneous frequency (MIF) 2 seconds before and after MAM, and (c) the time required for muscle spindle discharge (MF and MIF) to return to 95% of baseline after MAM. Depending on device setting, between 44% to 80% (Pulstar) and 11% to 63% (Activator V) of spindle afferents required >6 seconds to return to within 95% of baseline MF values; whereas 66% to 89% (Pulstar) and 75% to 100% (Activator V) of spindle responses returned to within 95% of baseline MIF in <6 seconds after MAM. Nonparametric comparisons between the 22 N and 44 N settings of the Pulstar yielded significant differences for the time required to return to baseline MF and MIF. Short duration (6 seconds) to return to baseline MF activity. Physiological consequences and clinical relevance of described MAM mechanoreceptor responses will require additional investigation.Keywords
This publication has 69 references indexed in Scilit:
- Relationship between Biomechanical Characteristics of Spinal Manipulation and Neural Responses in an Animal Model: Effect of Linear Control of Thrust Displacement versus Force, Thrust Amplitude, Thrust Duration, and Thrust RateEvidence-Based Complementary and Alternative Medicine, 2013
- Comparison of force development strategies of spinal manipulation used for thoracic painManual Therapy, 2012
- An updated overview of clinical guidelines for chronic low back pain management in primary careJoint Bone Spine, 2012
- Neurophysiologic effects of spinal manipulation in patients with chronic low back painBMC Musculoskeletal Disorders, 2011
- Synthesis of recommendations for the assessment and management of low back pain from recent clinical practice guidelinesThe Spine Journal, 2010
- Mechanical vs Manual Manipulation for Low Back Pain: An Observational Cohort StudyJournal of Manipulative and Physiological Therapeutics, 2010
- Effectiveness of manual therapies: the UK evidence reportChiropractic & Manual Therapies, 2010
- The mechanisms of manual therapy in the treatment of musculoskeletal pain: A comprehensive modelManual Therapy, 2009
- Intervertebral Disc Degeneration Reduces Vertebral Motion ResponsesSpine, 2007
- Response of lumbar paraspinal muscles spindles is greater to spinal manipulative loading compared with slower loading under length controlThe Spine Journal, 2007