First report of splenic rupture following deep enteroscopy
Open Access
- 1 January 2016
- journal article
- Published by Baishideng Publishing Group Inc. in World Journal of Gastrointestinal Endoscopy
- Vol. 8 (9) , 391-4
Abstract
Splenic rupture is a rare complication of diagnostic and therapeutic gastrointestinal endoscopy procedures. Herein, we report for the first time a case of splenic rupture following therapeutic retrograde double-balloon enteroscopy, which occurred in an 85-year-old man who was treated for recurrent mid-intestinal bleeding that resulted from ileal angioectasia. This patient promptly underwent an operation and eventually recovered.Keywords
This publication has 16 references indexed in Scilit:
- Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Clinical GuidelineEndoscopy, 2015
- Double-Balloon Enteroscopy in Elderly Patients: Is It Safe and Useful?Intestinal Research, 2014
- Splenic Injury During Colonoscopy—a Complication that Warrants Urgent AttentionJournal of Gastrointestinal Surgery, 2012
- Long-term outcome after argon plasma coagulation of small-bowel lesions using double-balloon enteroscopy in patients with mid-gastrointestinal bleedingEndoscopy, 2011
- Splenic Injury as a Complication of Colonoscopy: A Case SeriesAmerican Journal of Gastroenterology, 2009
- Endoscopic classification of vascular lesions of the small intestine (with videos)Gastrointestinal Endoscopy, 2008
- Splenic Rupture After Colonoscopy2007
- Push-and-Pull Enteroscopy using the Double-Balloon Technique: Method of Assessing Depth of Insertion and Training of the Enteroscopy Technique using the Erlangen Endo-TrainerEndoscopy, 2005
- Splenic Injury: A Rare Complication of Endoscopic Retrograde CholangiopancreatographyThe American Surgeon™, 2004
- Barriers to incident reporting in a healthcare systemQuality and Safety in Health Care, 2002