Multicenter Evaluation of the BACTEC MGIT 960 System for Recovery of Mycobacteria
Authors:
- 1 March 1999
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 37 (3) , 748-752
Abstract
We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC MGIT 960 and BACTEC 460 TB systems, as well as onto Lowenstein-Jensen slants and Middlebrook 7H11/7H11 selective plates. From all culture systems, a total of 362 isolates of mycobacteria were recovered; these were recovered from 353 specimens collected from 247 patients. The greatest number of isolates of mycobacteria (289, or 80% of the 362 isolates) was recovered with the BACTEC MGIT 960, followed by the BACTEC 460 TB (271, or 75%) and solid media (250, or 69%). From all culture systems a total of 132 isolates of Mycobacterium tuberculosis complex were recovered. The greatest number of isolates of M. tuberculosis complex was recovered when liquid medium was combined with conventional solid media; the number recovered with BACTEC 460 TB plus solid media was 128 (97%), that recovered with BACTEC MGIT 960 plus solid media was 121 (92%), that recovered with BACTEC 460 TB was 119 (90%) and that recovered with all solid media combined was 105 (79%). The recovery with BACTEC MGIT 960 alone was 102 (77%). The mean times to detection (TTD) for M. tuberculosis complex were 14.4 days for BACTEC MGIT, 15.2 days for BACTEC 460 TB, and 24.1 days for solid media. The numbers of isolates of Mycobacterium avium complex (MAC) recovered were 172 (100%) for all systems, 147 (85%) for BACTEC MGIT 960, 123 (72%) for BACTEC 460 TB, and 106 (62%) for all solid media combined. The TTD for MAC in each system were 10.0 days for BACTEC MGIT 960, 10.4 days for BACTEC 460 TB, and 25.9 days for solid media. Breakthrough contamination rates (percentages of isolates) for each of the systems were 8.1% for BACTEC MGIT 960, 4.9% for BACTEC 460 TB, and 21.1% for all solid media combined.Keywords
This publication has 14 references indexed in Scilit:
- Comparison of Roche Cobas Amplicor Mycobacterium tuberculosis Assay with In-House PCR and Culture for Detection of M. tuberculosisJournal of Clinical Microbiology, 1998
- Multicenter Comparison of ESP Culture System II with BACTEC 460TB and with Lowenstein-Jensen Medium for Recovery of Mycobacteria from Different Clinical Specimens, Including BloodJournal of Clinical Microbiology, 1998
- Evaluation of the MB/BacT system and comparison to the BACTEC 460 system and solid media for isolation of mycobacteria from clinical specimensJournal of Clinical Microbiology, 1997
- Evaluation of a nonradiometric system (BACTEC 9000 MB) for detection of mycobacteria in human clinical samplesJournal of Clinical Microbiology, 1997
- The Significance of Mycobacterium avium Complex Cultivation in the Sputum of Patients With Pulmonary TuberculosisChest, 1997
- Comparison of mycobacteria growth indicator tube with BACTEC 460 for detection and recovery of mycobacteria from clinical specimensJournal of Clinical Microbiology, 1996
- Current Approaches to the Diagnosis of Active Pulmonary TuberculosisAmerican Journal of Respiratory and Critical Care Medicine, 1994
- College of American Pathologists position statement regarding rapid detection of Mycobacterium tuberculosis.1993
- Evaluation of the BACTEC radiometric method for recovery of mycobacteria and drug susceptibility testing of Mycobacterium tuberculosis from acid-fast smear-positive specimensJournal of Clinical Microbiology, 1983
- Automatable radiometric detection of growth of Mycobacterium tuberculosis in selective media.1977